![Segger Flasher ATE User Manual Download Page 75](http://html1.mh-extra.com/html/segger/flasher-ate/flasher-ate_user-manual_1233803075.webp)
75
CHAPTER 8
ASCII command interface
#SELECT
The
#SELECT
command is used to select a specific configuration and data file pair which
should be used by the Flasher ATE to program the target.
Command structure:
#select [module1][,module2][,module3] “[Project Name]”
The select command expects the following parameters:
Parameter
Meaning
Project Name
The
[Project Name]
specifies the name of file pair without ex-
tensions (.CFG and .DAT) on the Flasher ATE modules which
should be selected. Flasher saves the selected configuration and
data file in the FLASHER.INI file. So this selection is remembered
even after power-cycling the Flasher ATE.
Example sequence:
Command send to
the Flasher ATE
Reply on the main channel
(RS232 or telnet connection)
Reply on the target
channel (telnet connection
to flash module)
#SELECT 1,2,3 “emPower”
#ACK
#OK
Flasher ATE User Guide (UM08035)
© 2017-2018 SEGGER Microcontroller GmbH