3−3 TROUBLESHOOTING
This section explains how to deal with trouble in the card recognition function, camera unit
(ASSY CCD CASE), and LED unit (ASSY LED L/R).
Refer to the Owner's Manual for details on how to replace each part.
The shutter speed is wrong despite automatic adjustment.
[CAUSE]:
The test sheet is not laid out correctly.
[COUNTERMEASURES]:
Lay the test sheet correctly on the field.
[CAUSE]:
Extraneous matter is trapped between the test sheet and the field
sheet.
[COUNTERMEASURES]:
Confirm that nothing is trapped between the test sheet and the
field sheet.
[CAUSE]:
The test sheet has been moved during automatic adjustment.
[COUNTERMEASURES]:
Perform automatic adjustment again without moving the test
sheet.
[CAUSE]:
Damage to the LED Unit
[CHECKING METHOD]:
Remove the field glass for the components and watch the LED
indication.
[COUNTERMEASURES]:
Replace the ASSY LED L/R.
[CAUSE]:
Damage to the Camera Board
[COUNTERMEASURES]:
Replace the ASSY CCD CASE.
The yellow circle is not displayed during camera position adjustment.
[CAUSE]:
The test sheet is not laid out correctly.
[COUNTERMEASURES]:
Lay the test sheet out correctly.
[CAUSE]:
The camera is wildly off-center relative to the field.
[CHECKING METHOD]:
Position the center of the test sheet just inside the field and see
whether the circle appears.
[COUNTERMEASURES]:
Turn the camera adjustment knobs to reduce the gap.
[CAUSE]:
The mounting position of the lens on the camera board is out of
alignment.
[COUNTERMEASURES]:
Replace the ASSY CCD CASE.
[CAUSE]:
The lens focus is out of alignment.
[COUNTERMEASURES]:
Replace the ASSY CCD CASE.