Mushiking#3-eng.doc
」
最終印刷日時:
2010/01/14 14:19:00
6/17
(P. 48)
14. COIN SELECTOR
REMOVING THE COIN SELECTOR
Loosen the plastic-head screw to raise the lever and open the coin
selector cover and then remove the coin selector.
REMOVING A JAMMED COIN
When the coin return button fails to refund coins, open the coin
chute door and open the selector gate. Once the jammed coin is
removed, insert a standard coin to ensure that the selector is
working properly.
FIG. 14a
CLEANING THE COIN SELECTOR
(STOP) IMPORTANT
●
Remove and clean smears using a soft cloth dipped in water or diluted
chemical detergent and then wrung dry.
●
Never apply machine oil, etc. to the coin selector.
●
After cleaning the coin selector, properly insert a standard coin to ensure that
the selector functions correctly.
The coin selector should be cleaned once every 3 months. When cleaning, follow the procedures below:
1. Turn off the main AC unit power switch and open the coin chute door.
2. Open the gate and remove dust using a soft brush (made of wool, etc.).
3. Remove and clean smears by using a soft cloth dipped in water or diluted chemical detergent and then
wrung dry.
4. Remove the cradle. When detaching the retaining ring (E ring), be extra careful not to bend the rotational
axis.
5. Use a soft cloth to wipe any dirt/debris off the rotational axis and bearings.
6. After wiping as described in the previous step, use a dry cloth, etc. to dry the coin selector completely.
COIN INSERTION TEST
Once every month, when performing the Coin Switch Test, check the following points:
□
Does the Coin Meter count properly?
□
Do coins drop into the Cashbox correctly?
□
Are coins rejected when inserted while holding down the Reject Button?
LEVER
COIN SELECTOR COVER