Notes:
- Be sure to turn the power off and on again when inserting/removing Management Chips, even if the
machine is in use.
- The counter in the Management Chip is set for the number of cards in one carton, and each dispensed card
reduces the counter number by 1. One Management Chip allows game operation for one carton of cards.
When the credits reach zero and the warning screen
is displayed, install a new Management Chip.
A Management Chip that causes the “EMPTY
LAMP” to light up cannot be used.
There are two reader/writer units. If the chip is
recognized by either one of them, the game can be
operated.
The status of the chip can be verified in Test Mode.
PHOTO 7-1
FIG. 7-1
MANAGEMANT CHIP INDICATORS
●
POWER LAMP: The green lamp lights up when the machine has properly recognized the reader/writer
units.
●
BUSY LAMP: The red lamp flashes when the reader/writer is communicating with the Management
Chip. Do not remove the Management Chip when the lamp is blinking. In addition, do not turn the power
off or perform any other operations on the machine.
●
EMPTY LAMP: This lamp lights up when either the credits for the Management Chip reach zero or
when an error has occurred with the Management Chip reader/writer.
(P. 20)
《新ページとして追加して、以下21~60までをページ送る。》
7-2 MANAGEMENT CHIP ERROR CODES
減算チップ
(
Management Chip
)
関係で不具合が発生した場合には、下記のエラーコードを画面に
表示します。次の「原因」と「対処方法」を参照して、適切に対処してください。
ERROR 50:
マネジメントチップ
リーダ/ライタ
エラー
[DISPLAY]
ERROR 50
RFID READER NOT READY
(
テストモードで発生した場合は、
”READER NOT READY”
を表示。
)
[CAUSE]
断線またはハードの故障等で通信が成立しない場合。
[COUNTERMEASURES]
配線接続が正しく接続されていない。あるいは断線の恐れがあ
ります。配線接続を確認してください。また、マネジメント
リーダ/ライタの故障が考えられ
ます。交換をしてください。
ERROR 51:
マネジメントチップ
の読込みエラー
[DISPLAY]
ERROR 51
RFID READ ERROR
POWER LAMP
BUSY LAMP
EMPTY LAMP