33
Ausgabe
issue
D / 04.02.2013
Dokument
document
OM.SCT.02e
Blatt
sheet
11 (18)
9
Dismantling/reassembly
9.1.3.5 Segment retainer (671) - dismantling - pressure branch
9.1.3.6 Rotating unit (RTE) – Dismantling
with flush connection
without flush connection
Dismantle the segment retainer (671) on
the suction casing (500).
Remove the O-ring (731) from the centring
recess on the suction casing (ZA, 500).
Tool (W10/dismantling tool)
Remove the flushing connection (SSÜ) on
the casing of the shaft seal (SEA).
Lift/slide splash ring (310) and turn out
plug-in shaft pin (309).
Pull the rotating unit (RTE) with shaft seal
(SEA) off from the output shaft of the drive
(ANT).
Dismantle shaft seal (SEA).
–
Note dismantling the shaft seal
(chapter 9._).
Tool (W10/dismantling tool)
Lift/slide splash ring (310) and turn out
plug-in shaft pin (309).
Pull the rotating unit (RTE) with shaft seal
(SEA) off from the output shaft of the drive
(ANT).
Dismantle shaft seal (SEA).
–
Note dismantling the shaft seal
(chapter 9._).