83
Parameter Function
Relay Out Enable alarm activation function. You need to select alarm output port
so that system can activate corresponding alarm device when alarm
occurs.
For 6-ch alarm output port device, the 6
th
channel is the controllable
+12V output.
Alarm
Latch
System can delay the alarm output for specified time after alarm end
The value ranges from 10 seconds to 300 seconds.
Record
Channel
System auto activates current channel to record once alarm
occurs (working with alarm activation function). Please note
current device shall be in auto record mode
Record
Latch
System can delay the record for specified time after alarm ended. Th
value ranges from 10s to 300s.
Email
Please draw a circle to enable email function. System can send out
email to alert you when alarm occurs and ends.
Screen
display
After enabled, alarm info will be prompted out on the local output
end. That is to say, the alarm prompt will be displayed beside the
channel name on the local surveillance image.
Buzzer
Once you check the box here, the buzzer beeps when an alarm
occurred.
Tour
z
Display the selected video in local monitor window. When
alarm occurs, system can begin one-window tour for the activated
record channel. Please set the tour time in the local end.
PTZ
activation
z
Here you can set PTZ movement when alarm occurs. Such as
go to preset x when there is an alarm.
z
The PTZ configuration events include preset, tour, and pattern.
Copy
It is a shortcut menu button. You can copy current channel setup to
one or more (all) channels.
5.3.2.1 Detect
By analyzing video image, system will boot video detection alarm when it senses the motion
signal which meets the senility standard that is previously set. See Figure 5-35.