ProLogic L02-C 

Operation Instructions 

 

 

 

ProLogic L02-C Operation Instructions 
Document No: EC-0601A-L02-C-160617 
Version No: V1.01  
 
1.0 System Installation 
1.1 System Components 
1.2 Pairing the EntryPad with the Lock(s) 
1.3 Lock and EntryPad Installation 
1.4 Installing Battery 
1.5 Test Lock Operation 
 
2.0 Lock Operation
 
2.1 Opening the Lock 
2.2 Opening the Lock in Time Delay 
2.3 Opening the Lock in Dual Control 
2.4 Opening the Lock with a Multi-Lock System 
 
3.0 Code Management
 
3.1 Code Length Options 
3.1.1 PW L – 6 / Users 10 
3.1.2 PW L – 8 / Users 30 
3.1.3 PW L – 6 / Users 30 
3.2 Enrolling New users 
3.3 Change Code 
3.4 Delete One User 
3.5 Delete All Users 
3.6 Disable/Enable User 

3.7 Obfuscate Code Entry 
 
4.0 System Identification
 
4.1 System Info 
 
5.0 Time Delay
 
5.1 Set/Cancel Time Delay 
5.2 Setting Time Delay Override Users 
 
6.0 Single or Dual Control
 
6.1 Enable Dual Mode 
6.2 Dual Mode Group ID 
 
7.0 Manager Mode 
7.1 Enable Manager Mode 
7.2 Disable Manager Mode 
 
8.0 Door Management
 
8.1 Configuring a Multi-lock system 
8.2 Set Number of Locks 
8.3 Authorize Locks 
8.4 Enable Sequence 
 
9.0 Data Management 
9.1 Encryption Key Set 
 
10.0 Recovering the System – Reset to Default
 
10.1 Recovery Code Set 
10.2 Recover System 
10.4 Mechanical Reset 
 
11.0 System Testing 
11.1 Cycle Testing 
 
12.0 Menus 
12.1 The ProLogic L02-C Menus 

 

 

 

IMPORTANT:  It is imperative that all programming be completed with the safe 
door in its open position, such that the programmer can gain access to the lock 
body in the event of an incorrect programming.   

 

Summary of Contents for ProLogic L02-C

Page 1: ...sable Enable User 3 7 Obfuscate Code Entry 4 0 System Identification 4 1 System Info 5 0 Time Delay 5 1 Set Cancel Time Delay 5 2 Setting Time Delay Override Users 6 0 Single or Dual Control 6 1 Enabl...

Page 2: ...the lock must also be programmed in digital mode Both modes follow the same steps to reset set which is done by following the steps detailed below Step 1 Ensure the battery is connected to the Entry P...

Page 3: ...oor you will see the lock mounting plate and the predrilled lock mounting holes Connect the lock cable to the lock body and position the lock body appropriately on the lock mounting plate Ensure that...

Page 4: ...he EntryPad See Fig 5 Install a new 9V alkaline battery Duracell or Energizer brands are recommended into the compartment The battery compartment will only receive the battery when the positive and ne...

Page 5: ...s Fail to Link with Lock proceed to Section 1 2 entitled Pairing the EntryPad and the Lock 2 1 Opening the Lock The safe lock system has two default codes installed as follows Super Code ID00 1 1 1 1...

Page 6: ...When Time Delay expires the EntryPad will beep twice then display Time Window XX 00 indicating the length of time the User has to enter a valid user code to gain entry The Counter will count down unt...

Page 7: ...put into service The ProLogic L02 C has the capability to add up to 29 codes in addition to the default codes ID02 is a Manager Code and therefore has management functionality the same as ID01 ID03 3...

Page 8: ...be displayed as follows Step 4 Scroll and to the menu selection PW L 6 Users 10 and Press OK Step 5 The LCD will display a warning followed by Delete All Users press OK to confirm All users have been...

Page 9: ...ss OK to confirm All users have been deleted IMPORTANT The LCD will advise if a reset is required to finalize the programming If required follow the Mechanical Reset procedure outlined in 9 4 Mechanic...

Page 10: ...e that this setting does not meet the UL requirement Step 6 The LCD will then display a warning followed by Delete All Users press OK to confirm All users have been deleted IMPORTANT The LCD will advi...

Page 11: ...next available ID position is displayed To select this ID Press OK or to select a different ID position Press to desired ID and press OK Step 6 Now enter a 6 digit code Step 7 Repeat new code Step 8 S...

Page 12: ...vailable for use 3 4 Delete One User Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and Press Menu OK Step 3 The display will prompt you to enter a valid code Enter eith...

Page 13: ...ou to enter a valid code Enter either the Super Code ID00 or the Manager Code ID01 The Select Menu message will be displayed as follows Step 4 Scroll UP to the menu selection Delete All Users and Pres...

Page 14: ...k which User to disable Scroll and to the desired USER ID and press OK Step 6 The system will verify the User has been disabled 3 7 Obfuscate Code Entry This feature would be used in order to obfuscat...

Page 15: ...System Identification This menu feature would be used to determine the type of safe lock system being used Many of the SecuRam ProLogic EntryPads look the same but the features sets and capabilities...

Page 16: ...ter a valid code Enter either the Super Code ID00 or the Manager Code ID01 The Select Menu message will be displayed as follows Step 4 Scroll UP to the menu selection Set Cancel Time Delay and Press O...

Page 17: ...1 and the set ID number will have TDO authority When TDO is set to ID01 only ID00 and ID01 have TDO authority When TDO is set to ID00 only ID00 has TDO authority 6 0 Single or Dual Control The ProLogi...

Page 18: ...a User Code from ID00 to ID15 Group A must be entered with a second code from ID16 ID30 Group B in order to open the safe lock Also Manager Codes are no longer Dual Mode Overide Codes You can set thi...

Page 19: ...s enabled the Manager Codes ID01 and ID02 are not used to open the safe When entered these codes alternately toggle on off the User Codes For example the User codes have been enabled all day but now t...

Page 20: ...e Manager Mode This menu selection allows you to set the Manager Mode as described above Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and Press OK Step 3 The display w...

Page 21: ...e Enter either the Super Code ID00 or the Manager Code ID01 The Select Menu message will be displayed as follows Step 4 Scroll to the menu selection Set Number of Locks and Press OK Step 5 The system...

Page 22: ...d User ID Press OK Step 7 Next the LCD will display the current settings for these users In the example below this group of users is authorized to open Lock 1 but it does not have access to Locks 2 3...

Page 23: ...e selected inner compartment lock will open 9 0 Data Management As a security measure all data that is transmitted between the EntryPad and lock is encrypted such as User codes etc 9 1 Encryption Key...

Page 24: ...alpha numeric code must be deciphered using SecuRam s Authorization Code Generator Software The alpha numeric code is entered into the software together with the encryption code Through the software...

Page 25: ...call an authorized SecuRam Recovery Center or SecuRam Tech Support at 1 805 988 8088 for an Authorization Code This code remains valid for a period of 20 minutes only Step 7 After receiving the One T...

Page 26: ...display will prompt you to enter the Recovery Code Enter the existing Recovery Code The default recovery Code is 999999 Step 4 The LCD screen will display an alpha numeric number random key Record thi...

Page 27: ...tes in digital mode The ProLogic L02 C is a digital system and can be paired with any SecuRam safe lock body Note The pairing of the StrikeBolt and the ProLogic L02 C EntryPad is not UL listed If the...

Page 28: ...een successfully paired and the default codes will operate the lock If the LCD reports Fail to Link with Lock repeat the reset process 11 0 Testing The ProLogic L02 C has an onboard system test called...

Page 29: ...tion Instructions 29 The system will now cycle the motor drive system locking and unlocking the lock body every 1 5 seconds The cycle testing will continue until the battery depletes itself of energy...

Page 30: ...cryption Key Set Sub Menu Super Manager Codes Select Menu Change Code System Info Set TDO User ID Set Cancel Time Delay Obfuscate Code Entry Delete All Users Enable Sequence Authorize Locks Set Number...