PROGRAMMING

A. Procedure:

(1) Disarm the alarm.
(2) Turn the ignition switch ON then OFF.
(3) Within 15 seconds, press and release

the VEPLe button three times and turn

the ignition ON again.  The siren chirps

once.  (NOTE — The time from the

ignition switch OFF to the ignition switch

ON again should not exceed 15 sec.)

(4) Choose the feature to program —

Within 15 seconds, press and release

the VEPLe button the number of times

needed to select the feature to be

programmed.  The siren chirps once

each time the button is pressed and

released.  (NOTE — If the VEPLe button

is not pressed within 15 seconds, the

alarm exits the programming mode.)

(5) Toggle the feature ON/OFF — Within

15 seconds, press and hold the VEPLe

button to turn the feature ON or OFF.

The siren continually alternates between

1 and 2 chirps to confirm whether the

feature is ON or OFF.  Release the

VEPLe button after you hear 1 chirp

(feature ON) or 2 chirps (feature OFF).

(NOTE — If the button is not pressed

within 15 secs., the alarm exits

programming mode.)

(6) To program other features, press and

release the VEPLe button the number of

times to reach the next feature.  For

instance, if you just programmed

feature no. 2, and now want to

program feature no. 4, press and

release the VEPLe button 2 more times.

Then press and hold the VEPLe button to

turn the feature ON or OFF as per step

(5).  (NOTE — You must press the VEPLe

button within 15 seconds of the last

press of the button.)

Notes: *1 Does not affect programming chirps or learning chirps.

*2 For BROWN/WHITE wire only.

*3 If Off, alarm chirps once when armed manually, whether door is open or closed.

If On, alarm chirps 3 times to show if a door is open when armed, but also if

delayed domelight is On.

*4 Lock output becomes 25 sec., but unlock support doesn’t change. For specific

autos like late-model VWs.

*5 If N.O. starter disable is selected, loop LP1 must be cut. See page 16.

Choose

Description of feature

Confirm chirps - VEPLe button press

Default

feature chirps

1 chirp (on)

2 chirps (off)

setting

1

Alarm chirps

on

off

on (*1)

2

Passive/active mode

active

passive

active

3

Secure Lock™

off

on

off

4

Current Sensor

off

on

off

5

Ignition-controlled door lock

off

on

off

6

Ignition-controlled door unlock

off

on

off

7

Ignition off, domelight turns on

off

on

off

8

Pulsed (horn) or continuous (siren) output

pulsed

continuous

pulsed(*2)

9

Door error indicator On/Off

on

off

on (*3)

10

Mercedes Benz one-wire system

off

on

off

11

Door lock/unlock timing

0.5 sec.

3.5 sec.

0.5 sec.

12

Comfort mode

off

on

off (*4)

13

Double-pulse unlock

off

on

off

14

Starter disable output (must also cut loop for N.O.)

N.C.

N.O.

N.C. (*5)

15

Exit program procedure (no feature)

n/a

n/a

n/a

Table C — Feature programming using the VEPLe button

Summary of Contents for Enforcer SLI 820A

Page 1: ...820A SLI 820R SLI 820R 4 SLI 820RTC SLI 820RTC 4 SLI 820RTF SLI 820RTF 4 315 MHz 433 92 MHz Factory Keyless Entry Alarm Adapter Security System SECO LARM U S A INC 16842 Millikan Avenue Irvine Califo...

Page 2: ...tion Diagram 4 Specifications 5 Mounting the Alarm Brain 5 Wire connections For all vehicles 8 pin connector RED wire 12 volts 6 3 x ORANGE wires parklights 6 7 BLACK wire ground 7 WHITE wire starter...

Page 3: ...not impair or interfere with the normal operation of the car s moving parts 7 Mount all components and run all wires so they cannot be easily reached from underneath the vehicle BEFORE YOU START DON...

Page 4: ...D Flashing parking light output Relay 7 5A max ORANGE ORANGE ORANGE Channel 2 output 200mA max Car horn output 200mA max Hood trunk trigger input Door trigger input Door trigger input Neg door switch...

Page 5: ...drain Under 10mA disarmed Under 30mA armed LED flashing Exit delay 30 seconds passive arming Entry delay None Alarm duration 30 second cycle max 3 cycles MODEL NO REFERENCE l SLI 820A Excludes RF tra...

Page 6: ...or parking light wire varies when you dim or brighten the interior lights then this is not the correct wire B Connect the fused ORANGE WIRE 1 Positive parking light system Connect the fused ORANGE WI...

Page 7: ...grounding lug and star washer Connector 2 8 pin connector WHITE WIRE to starter disable figs 3a 3b Connect to an optional 30A relay to prevent the car from starting when the alarm is armed A Locate th...

Page 8: ...sually in the driver s kick panel which shows 12VDC when any vehicle door is open and which is not 12VDC when all the doors are closed Connect to the PURPLE WIRE Connector 3 6 pin connector BLUE WHITE...

Page 9: ...lay to control trunk release or other accessory NEVER CONNECT THE BLACK WHITE WIRE DIRECTLY TO AN OPTIONAL ACCESSORY AS THIS WILL BURN OUT THE 2ND CHANNEL OUTPUT AND POSSIBLY THE ENTIRE ALARM BRAIN Co...

Page 10: ...with a VOM meter unlock all the doors via the OEM remote The passenger door unlock wire changes status during the unlock operation There are four main types of keyless entry systems Connect the 3 pin...

Page 11: ...Switches Door Lock Relay Lock switch wire Unlock switch wire Lock switch wire Unlock switch wire OEM Keyless Module X X BROWN BLUE GREEN Insert Diode Fig 12 Factory arm disarm for vehicles WITH driver...

Page 12: ...ck switch has 3 wires One wire always shows ground The LOCK WIRE becomes ground when the door is locked and sends a pulse to a factory relay to lock the doors The UNLOCK WIRE becomes ground when the d...

Page 13: ...e positive shunt switching Factory door lock actuators Actuator control module 12VDC Factory lock unlock switch 12VDC 8 Cut GRAY to lock 200mA max 8 12VDC BROWN to unlock 200mA max BROWN to unlock 200...

Page 14: ...causes the doors to unlock and removing the 12VDC not applying ground causes the doors to lock Found on some Ford Probes See fig 20 F Single wire negative shunt switching This system uses a single wir...

Page 15: ...ensitivity is set to minimum the shock sensor cannot trigger the alarm equivalent to turning the shock sensor OFF Pre intrusion is also turned OFF c When sensitivity is set to maximum the shock sensor...

Page 16: ...ening of a door it is possible the domelights do not draw enough current In this case try a brighter domelight check the vehicle CURRENT SENSING SWITCH SENSING Programming and auxiliary functions IMPO...

Page 17: ...once Table B Chart of VEPLe button operations VEPLe BUTTON push button CODE LEARNING The VEPLe button is a 4 function push button switch It is used for entering and exiting the valet mode emergency d...

Page 18: ...lease the VEPLe button 2 more times Then press and hold the VEPLe button to turn the feature ON or OFF as per step 5 NOTE You must press the VEPLe button within 15 seconds of the last press of the but...

Page 19: ...ary sensors and Current sensing 60 second delay for factory remote and 4 second delay for the optional ENFORCER remote D Triggered zone recall When the alarm is armed trigger any one zone of the car T...

Page 20: ...or broken or its height is not adjusted properly Door switches are isolated by diodes Shock sensor or door pin switches or current sensing Alarm detects open circuit does zone bypass Set for chirp del...

Reviews: