(4) Within 15 seconds, push any button of

the first transmitter to be learned.  At this

time, all previous codes are deleted, and

the alarm learns this transmitter's code.

1 chirp confirms code is learned.  (If no

button is pressed within this 15-second

period, code learning is exited, and old

codes are retained.)

(5) Within 15 seconds, push any button of

the second transmitter to be learned (if

applicable).  1 chirp confirms learned.

(6) Repeat step (5) until all transmitters are

learned.  The siren chirps once for each

transmitter when its code is successfully

learned.

B. Exit the code learning procedure — The

alarm chirps the siren two times, exits the

code learning mode, and is disarmed after

learning the fourth transmitter's code, or if

you turn the ignition switch ON, or if you do

nothing for 15 seconds.

Note – This section applies only if the optional

ENFORCER remotes are used.
The alarm can learn a max. of 4 remotes.  RF

Code Wash™ deletes all previous remotes when

any new remote is learned.  This prevents

unauthorized use of lost or stolen transmitters,

and, because the user's transmitter no longer

works, alerts the user if someone has secretly

code learned a new transmitter.  However, it also

means that, when code learning is being done,

ALL THE USER'S TRANSMITTERS MUST BE CODE

LEARNED AT THE SAME TIME.
A. Procedure:

(1) Disarm the alarm.
(2) Turn ignition switch ON, then OFF, then

ON, then OFF.

(3) Press the VEPLe button three times within

15 secs. of turning the ignition OFF.  The

siren chirps once.

Table B — Chart of VEPLe button operations:

VEPLe BUTTON (push-button)

CODE LEARNING

The VEPLe button is a 4-function push-button

switch.  It is used for entering and exiting the

valet mode, emergency disarm, programming,

and code learning.

Table B shows how the VEPLe button is used.

Enter polarity learn mode
Disarmed
Turn ON
Within 15 sec. press and

hold VELPe switch for 4 sec.
Chirp once

The alarm is now in the

polarity learn mode
OFF
Turn ignition OFF to exit

polarity learn mode, siren

will chirp twice

Step

Initial status
Ignition sw.
VEPLe button

Siren/light

confirm

Status

LED
Note

Exit valet mode
Valet mode
Turn from OFF to ON
Press 3 times within

15 sec. of ignition ON
Chirp twice and flash

twice after VEPLe

pressed 3rd time
The alarm is now

disarmed
OFF

E: Emergency disarm

Armed or triggered
Turn from OFF to ON
Press 3 times within

15 sec. of ignition ON
Chirp 3 times & flash

3 times after VEPLe

pressed 3rd time
The alarm is now in

the valet mode
Slow flashes
Procedure is the same

as valet mode

Enter Valet mode
Disarmed
Turn from OFF to ON
Press 3 times within

15 sec. of ignition ON
Chirp once and flash

once after VEPLe

pressed 3rd time
The alarm is now in

the valet mode
Slow flashes

Enter code learning
Disarmed
Turn ON/OFF/ON/OFF
Press 3 times within 15

sec. of ignition OFF
Chirp once after VEPLe

pressed 3rd time

The alarm is now in the

code learning mode
OFF
Inactivity for 15 seconds

will exit code learning

mode

V: Valet mode enter and exit

Disarmed
Turn ON/OFF
Press 3 times within 15

sec. of ignition OFF
Chirp once after both

pressing VEPLe 3 times

and turning ignition ON
The alarm is now in the

programming mode
OFF
Inactivity for 15 sec.  will

exit programming mode

L: Learning

P: Programming

Summary of Contents for Enforcer SLI 820A

Page 1: ...820A SLI 820R SLI 820R 4 SLI 820RTC SLI 820RTC 4 SLI 820RTF SLI 820RTF 4 315 MHz 433 92 MHz Factory Keyless Entry Alarm Adapter Security System SECO LARM U S A INC 16842 Millikan Avenue Irvine Califo...

Page 2: ...tion Diagram 4 Specifications 5 Mounting the Alarm Brain 5 Wire connections For all vehicles 8 pin connector RED wire 12 volts 6 3 x ORANGE wires parklights 6 7 BLACK wire ground 7 WHITE wire starter...

Page 3: ...not impair or interfere with the normal operation of the car s moving parts 7 Mount all components and run all wires so they cannot be easily reached from underneath the vehicle BEFORE YOU START DON...

Page 4: ...D Flashing parking light output Relay 7 5A max ORANGE ORANGE ORANGE Channel 2 output 200mA max Car horn output 200mA max Hood trunk trigger input Door trigger input Door trigger input Neg door switch...

Page 5: ...drain Under 10mA disarmed Under 30mA armed LED flashing Exit delay 30 seconds passive arming Entry delay None Alarm duration 30 second cycle max 3 cycles MODEL NO REFERENCE l SLI 820A Excludes RF tra...

Page 6: ...or parking light wire varies when you dim or brighten the interior lights then this is not the correct wire B Connect the fused ORANGE WIRE 1 Positive parking light system Connect the fused ORANGE WI...

Page 7: ...grounding lug and star washer Connector 2 8 pin connector WHITE WIRE to starter disable figs 3a 3b Connect to an optional 30A relay to prevent the car from starting when the alarm is armed A Locate th...

Page 8: ...sually in the driver s kick panel which shows 12VDC when any vehicle door is open and which is not 12VDC when all the doors are closed Connect to the PURPLE WIRE Connector 3 6 pin connector BLUE WHITE...

Page 9: ...lay to control trunk release or other accessory NEVER CONNECT THE BLACK WHITE WIRE DIRECTLY TO AN OPTIONAL ACCESSORY AS THIS WILL BURN OUT THE 2ND CHANNEL OUTPUT AND POSSIBLY THE ENTIRE ALARM BRAIN Co...

Page 10: ...with a VOM meter unlock all the doors via the OEM remote The passenger door unlock wire changes status during the unlock operation There are four main types of keyless entry systems Connect the 3 pin...

Page 11: ...Switches Door Lock Relay Lock switch wire Unlock switch wire Lock switch wire Unlock switch wire OEM Keyless Module X X BROWN BLUE GREEN Insert Diode Fig 12 Factory arm disarm for vehicles WITH driver...

Page 12: ...ck switch has 3 wires One wire always shows ground The LOCK WIRE becomes ground when the door is locked and sends a pulse to a factory relay to lock the doors The UNLOCK WIRE becomes ground when the d...

Page 13: ...e positive shunt switching Factory door lock actuators Actuator control module 12VDC Factory lock unlock switch 12VDC 8 Cut GRAY to lock 200mA max 8 12VDC BROWN to unlock 200mA max BROWN to unlock 200...

Page 14: ...causes the doors to unlock and removing the 12VDC not applying ground causes the doors to lock Found on some Ford Probes See fig 20 F Single wire negative shunt switching This system uses a single wir...

Page 15: ...ensitivity is set to minimum the shock sensor cannot trigger the alarm equivalent to turning the shock sensor OFF Pre intrusion is also turned OFF c When sensitivity is set to maximum the shock sensor...

Page 16: ...ening of a door it is possible the domelights do not draw enough current In this case try a brighter domelight check the vehicle CURRENT SENSING SWITCH SENSING Programming and auxiliary functions IMPO...

Page 17: ...once Table B Chart of VEPLe button operations VEPLe BUTTON push button CODE LEARNING The VEPLe button is a 4 function push button switch It is used for entering and exiting the valet mode emergency d...

Page 18: ...lease the VEPLe button 2 more times Then press and hold the VEPLe button to turn the feature ON or OFF as per step 5 NOTE You must press the VEPLe button within 15 seconds of the last press of the but...

Page 19: ...ary sensors and Current sensing 60 second delay for factory remote and 4 second delay for the optional ENFORCER remote D Triggered zone recall When the alarm is armed trigger any one zone of the car T...

Page 20: ...or broken or its height is not adjusted properly Door switches are isolated by diodes Shock sensor or door pin switches or current sensing Alarm detects open circuit does zone bypass Set for chirp del...

Reviews: