Programming the Super User Code (continued):
3.
Toggle operation of output #1 ON or OFF:
2580 # 7
NOTE:
•
This function is used to leave output #1 active for extended periods of time.
•
While output #1 remains active, the green LED remains lit.
•
Do not forget to deactivate this function after its use is no longer required.
•
It is recommended to only use this function with fail-safe locks.
•
All functions requiring use of the door sensor input are suspended while this function
is in use.
4. Temporarily pause or restart the timed output #1 auto-disable period:
2580 # 8
NOTE:
•
This function is used to enable the operation of output #1 if it was disabled using the auto-
disable function (see pages 22~23).
•
When the output #1 auto-disable function is inactive, the red LED will flash steadily. This
indicates that output #1 may now be used.
5.
Disable or enable output #1 (toggle, regardless of programming):
2580 # 9
NOTE:
•
This is used to prevent users from accessing the protected premises.
•
For more information on programming timed or toggle mode, see “Programming the Output
Mode and Output Timing” on page 20.
•
The red LED will remain steady on while output #1 is disabled.
•
For safety reasons, the egress button works regardless of whether output #1 is enabled or
disabled via the super user code.
•
The super user code continues to operate output #1 even while that output is disabled.