26
ENFORCER Vandal Resistant Flush-Mount Access Control Keypad
SECO-LARM U.S.A., Inc.
Programming the Egress Delay/Warning:
With most keypads, the egress button provides a simple way for someone inside a protected
premises to exit through a locked door by pressing a button instead of using a keypad. However,
in some situations, delaying the egress operation and/or providing some warning when the egress
button is used is desirable.
For example, in hospitals or schools, it may be desirable to delay the egress operation and provide
a warning to prevent patients or young children from easily leaving the protected area.
For simple egress with no delay or warning, do not change this setting. It is disabled by default.
When programming the egress delay/warning, use this general formula:
90 a bb #
90
– Program Egress Delay/Warning
A
– Egress Mode
BB
– Delay Time
Egress Modes:
There are four possible egress operation configurations for the
SK-1123-FDQ
:
•
1
Momentary contact with no warning (default) – Press the egress button momentarily. The
door opens instantly (default) or after the programmed relay time with no audible warning.
•
2
Momentary contact with warning beep – Press the egress button momentarily. The keypad
will beep for the programmed delay time before letting the door open, to warn that someone is
preparing to exit the protected area.
Programming the Door-Propped-Open Warning and Timing:
If the keypad is connected to an optional magnetic contact or other door protection switch or
device, the keypad can be programmed to beep when a door has been propped open. This
prompts authorized users to close a door that was not closed properly or to investigate a door that
may have been deliberately propped open.
•
Door-propped-open warning OFF (default):
81 0 #
•
Door-propped-open warning ON:
81 TTT #
NOTE:
•
TTT
represents the delay time, which can be set from 1 to 999 seconds.
•
The delay time provides time for a door to close normally before triggering the door-propped-
open warning.
•
The door-propped-open beeping will stop when the open door is closed.