9.6 Two Units Interlocked for Two Doors
The interlocked function is mainly used in banks, prisons, and other places where a higher level security is required.
When and only door 2 closed, read valid card/
PIN on access host, door 1 will open; when and only door 1 closed,
read valid card/
PIN on external reader, door 2 will open.
Remark: The valid card/PIN is only for users of Zone 1, users of zone 2 are invalid.
input
input
L
N
1N4004
1N4004
Input
AC100
-
240V
Door
Bell
Alarm
Door
Contact 1
Exit
Button 1
Lock
1
(
A
/
B
)
Lock
B Lock
A
Inside Door
Outside Door
Short
-
Circuit
Wire
Red Black Green White
Access Host (Enter Door 1
)
Door
Contact 2
Exit
Button 2
1N4004
1N4004
Lock
2
(
A
/
B
)
Lock
B Lock
A
Red Black Green White
External Reader(Enter Door 2)
L
N
1N4004
1N4004
Input
AC100
-
240V
Door
Bell
Alarm
Door
Contact 1
Exit
Button 1
Lock
1
(
A
/
B
)
Lock
B Lock
A
Inside Door
Outside Door
Short
-
Circuit
Wire
Red Black Green White
Access Host ( Enter Door
)
Red Black Green White
External Reader( Exit Door )
9.7 Anti-passback for Single Door
In this mode, access host install outside is for entering door, external reader inside for exiting door, they build up a
single door anti-passback system, access host is the anti-passback master unit.
The users can only enter door when read valid card on access host, and exit from the inside external reader. If without
the entering record from access host, the users cannot exit from the inside reader, also the users can't enter in twice
without the first exit record.
Remark: This is only for card users of Zone 1, PIN users of Zone 1 and all users of Zone 2 are invalid.
25