Sebury S Key-s User Manual Download Page 11

*

1

Master 
code #

1

User ID number  
# PIN #

1. The user ID number is any number among 
    1- 2000.
2. The PIN is any 4-6 digits,   digit must be 
    1 with the exception of 1234 which is reserved
3. Users can be added continuously without 
   exiting programming mode

st

1

To add 

PIN

 users

Add the card as for a card user
Press  *   exit from the programming mode, then allocate the card a 
PIN as follows:  

*     

Read card    1234#    PIN#    Repeat PIN # 

To add 

Card

 

and

 

PIN 

users

2

Card number  #

Read Card

User ID number #  

Note:  
> Users can be deleted continuously without 
    exiting programming mode
> To delete 

Card and PIN

 users just delete the 

    card

To delete

 Card

 users 

by card number

To delete

 Card

 

users by cards

To delete 

Card or PIN

 

users

3

0 #

Entry is by Card ONLY

1 #

2 #

Entry is by Card and PIN together

Entry is by either Card or PIN 
(Factory default setting)

To set valid 

Card

 users

To set valid 

Card and PIN

 users

To set valid 

Card or PIN

 

users

0~99 #  

0 = 50mS, factory default setting: 5

To set door relay time

4

Every time a valid card/tag read or PIN input, 
the relay will operate, for the pre-set relay 
pulse time. (Factory default setting)

0 #

Relay Setting- Pulse mode

5

*

Master 
code #

1

Every time a valid card/tag read or PIN input, 
the relay changes state, which will not turn back 
until read card/tag or input PIN again

Relay Setting-Toggle mode

1~10 # 

Note: The door will open only when read the valid 
card quantity up to the quantity set. It is only for 
Card ONLY Mode (Factory default setting: 1 )

To set open door by multi 
cards

6

User ID number # 
Card number # 
Card Quantity #

The card number must be consecutive
Card quantity is between 1-2000

To add a 

series cards 

users-

Block Enrollment

7

User Setting for Zone 2

*

Master 
code #

2

The method is same as Zone 1,  the only difference is the   digit of PIN for Zone 2 must be 2

st

1

Advanced Application (System setting)

0

*

Master 
code #

3

0~15#

Factory default setting: 0

To set facility code

Wiegand reader

Standalone for single door

Standalone for two doors

With external reader for two doors

Two units interlocked for two doors
Anti-passback for single door

Anti-passback for two doors

Automatic mode Factory default setting)

 (

To set working mode

0#

1#

2#

3#

4#

5#

6#

9#

1

26~37 # 

Factory default setting: 26

To set Wiegand format

To set keypad transmission 
format

Note: When device reset to factory default, the 
setting is still valid

0~2 # 

3

2

17

18

1  #

Summary of Contents for S Key-s

Page 1: ...dress 5 F Building 8 Xinwu Industrial Park Xili Nanshan District Shenzhen China Tel 86 755 82885464 Fax 86 755 82884565 P C 518055 www sebury com cn User Manual Before installation and use please read...

Page 2: ...nd Light Indication 8 Detailed Programming Guide 9 Advanced Application Various Working Mode Application 9 1 Wiegand Reader 9 2 Standalone for Single Door 9 3 Automatic Mode 9 4 Standalone for Two Doo...

Page 3: ...ircuit open circuit or other illegal ways Built in 125KHz and 13 56MHz card reader Digital backlit key the back light can be set to Normal ON Normal OFF or Human Approach ON Built in door bell and als...

Page 4: ...red Receiving Hole Infrared Emission Hole Card Swiping Area Door Bell Button 03 04 Before installation and use please read the Quick Installation Guide carefully 2 Quick Installation Guide Photosensit...

Page 5: ...g Area Door Bell Button Connect Wire Photosensitive Tamper Window Sound Hole Bracket Access Host Front Panel Logo Indicator Light Metal Button Keypad Infrared Receiving Hole Infrared Emission Hole Car...

Page 6: ...Host 12V GND D0 D1 Red Black Green White Exit Button OPEN1 GND Yellow Yellow Lock NC 1 12V 1N4004 Black Red 6 AC100V 240V N L Shortcircuitplugfor lock Blue Yellow Green Brown Remark 1 Pay attention to...

Page 7: ...ll be picked up once unlocking instruction received and it will be released when unlocking time is beyond COM Relay Contact NC Normal Close which is connected with COM normally NO Normal Open which is...

Page 8: ...d cards time interval can not exceed 5s the door will open Precondition 1 Set the door entry by card only 2 Set 2 10 for opening the door by multi cards 4 3 To unlock the door for card and PIN users R...

Page 9: ...ller there will be no ring back tone Automatic Mode In this mode when the access host connects to i Box it is standalone for single door If without smart controller it work as Wiegand reader automatic...

Page 10: ...Logo LED Light indication Change the master code 1 3 4 2 5 6 9 Read Manager Add Card Read Manager Delete Card Read duress card Zone 1 Read duress card Zone 2 8 digit duress PIN Zone 1 Note The digit m...

Page 11: ...me Factory default setting 0 Relay Setting Pulse mode 5 Master code 1 Every time a valid card tag read or PIN input the relay changes state which will not turn back until read card tag or input PIN ag...

Page 12: ...e done below settings Change Master Code Set Facility Code Set the card transmission format Set the keypad transmission format Set optional setting Anti Tamper alarm When LED level is low Logo light w...

Page 13: ...ed 1 Key Output in hex Output in Binary 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 B 0 A 0001 0010 0011 0100 0101 0110 0111 1000 1001 1011 0000 1010 Model 2 8 Bit The output data is transmitted in following...

Page 14: ...f Zone 2 on access host door 2 will open Remark The common card for Zone 1 and Zone 2 can only open door 1 sTouch s sKey s input L N 1N4004 1N4004 Input AC100 240V Door Bell Alarm Door Contact 1 Exit...

Page 15: ...k Green White External Reader EnterDoor 2 L N 1N4004 1N4004 Input AC100 240V Door Bell Alarm Door Contact 1 Exit Button 1 Lock 1 A B Lock B Lock A Inside Door Outside Door Short Circuit Wire Red Black...

Page 16: ...ch is normally used for parking lot The users can only enter door 1 when read valid card on access host and exit from door 2 when read valid card on external reader If without the entering record from...

Page 17: ...them to other 4 6 digits Alarm under normal situation Light leaking when install access host Leaning on wall closely when install access host No reaction when reading card Machine is not on standby st...

Page 18: ...Bungs 1 6X30 mm 4X25 mm 2 Power Connecting Wire 1 2 Name Quick Use Guide Fixing Location Sticker Self Tapping Screw Rubber Bungs Qty 1 4 Remark 6X24 mm 3X20 mm 4 2 1 Screw Driver Diode 2 3 Manager Ca...

Reviews: