7. Sound and Light Indication
Operation Status
Standby
Press Key
Read Card
Door Open
Operation Successful
Operation Failed
PIN Inputting
Card & PIN Reading
Multi Card Reading
Start Menu
Sub enu
M
Under Setting
Manager Card Ente
r
Manager Card Exit
Alarm
Ring-back Tone
Logo Color
White
Green
Red
Green
Green
Red
Red
Slow Shine in White
Red
Orange
White
Quick Shine in Red
Orange
Buzzer
Short Ring
Long Ring
Long Ring
Long Ring
3 Short Ring
2 Short Ring
Long Ring
Alarm
Ding-Dong
8. Detailed Programming Guide
Standby
*
0
0
New master code # Repeat new master code #
(Note: Code length:6~8 digits, factory default :888888)
Master
code
Start
Menu
Sub
Menu
Setting
Remarks
Functions
White
Red
White Flash
Red
Orange
Master
code #
Administrator setting
Logo LED Light indication
Change the master code
1
3
4
2
5
6
9
Read Manager Add Card
Read Manager Delete Card
Read duress card (Zone 1)
Read duress card (Zone 2)
8-digit duress PIN # (Zone 1) (Note: The digit must be 1)
st
1
8-digit duress PIN # (Zone 2)
(
Note: The digit must be 2)
st
1
0000 # (Note: This is a dangerous option, so use with care)
Set Manager Add Card
Set Manager Delete Card
To set duress users
(
Note: There are only one duress
card and one PIN available for each
Zone. When input duress PIN/card,
the door will open, at the same time,
the external alarm operates.)
Delete ALL users
User Setting for Zone 1
*
1
Master
code #
1
Read card
User ID number
# read card
Card number #
ID number #
Card number #
1. The user ID number is any number among
1- 2000.
2. Card number must be 8 or 10 digits, if the
card number is less than 8 or 10 digits, input
0 before the card number
3. Users can be added continuously without
exiting programming mode
To add
Card
users
15