13 Rev. 1.2 13/01/2021
and closing cycle, or previously disable deceleration (see
function
C7
), so that when programming motor time, the
deceleration phase will be automatically excluded.
During programming the radio control key of the control
unit can be used instead of the SET key, if stored
previously.
A8) PAUSE T.:
(Automatic closing time programming max. 4
minutes)
The control unit is supplied by the manufacturer without
automatic closing. If you want to enable automatic closing,
proceed as follows: set SEL and SET to display
A8
then
press SET to select the function. At the same time
DOT 1
will start to flash, press SET briefly and also
DOT 2
will
start to flash. At the same time, the Display will scan the
Pause time seconds to Memorise, wait for the time
desired; briefly press the SET key again,
DOT 2
will
remain lit permanently and simultaneously memorise the
automatic closing time.
If you want to restore the original status (without
automatic closing), set SEL and SET to display
A8
, then
press SET to select the function. At the same time,
DOT 1
will start to flash, press SET for a few seconds,
DOT 1
and
DOT 2
will go off and the procedure will be complete.
A9 ) T. RIT. ANTE :
(Programming door delay of 15 sec. Max.)
The control unit is supplied by the manufacturer without
gate delay during opening and closing. If automation
configuration is used with 2 motors, it may be necessary
to enter the door delay time; follow this procedure for
programming with the shutter closed:
set SEL and SET to display
A9
then press SET to select
the function. At the same time
DOT 1
will start to flash,
press SET briefly and also
DOT 2
will start to flash. At the
same time, the Display will scan the Doors Closing Delay
time seconds, wait for the time desired; briefly press the
SET key again,
DOT 2
will remain lit permanently and
simultaneously memorise the Opening Doors Delay time
fixed at 2 seconds, the Doors Closing Delay time for the
programmed time.
If you want to restore the original status (without and Door
Delay), set SEL and SET to display
A9
, then press SET to
select the function. At the same time,
DOT 1
will start to
flash, press SET for a few seconds,
DOT 1
and
DOT 2
will
go off and the procedure will be complete.
Attention:
If previously selected the 1 Motor operating mode,
the selection of the delay time is disabled.
CONFIGURATIONS MENU “ B ”
The control unit is supplied by the manufacturer with the
possibility of selecting a number of important functions.
-----------------
CONFIGURATIONS MENU “ B ” --------------
Digit Reference DOT 2 Off DOT 2 On
B1) OPENING CMD INB. NO YES
B2) AUTOMATIC OPERATION STEP/STEP
B3) WATER HAMMER NO YES
B4) CLOSING HAMMER NO YES
B5) FOLLOW ME NO YES
B6) REMOTE TX PGM NO YES
B7) ELECTRONIC BRAKE NO YES
B8) SOFT START NO YES
B9) SOFT STOP NO YES
B1) OPENING CMD. INB. (Opening command inhibition):
The command inhibition function during opening is used, for
example, when automation includes a loop detector. During the
opening or pause phase, the control unit does not respond to
commands sent by the loop detector with every passage.
The control unit is supplied by the manufacturer with the
Opening Command Inhibition function disabled. If you want to
enable the function, proceed as follows: set SEL and SET to
display
B1
then press SET to select the function. At the same
time
DOT 1
will start to flash, press SET to change the function,
DOT 2
will remain permanently lit and the operation will be
complete.
Repeat the procedure to restore the previous configuration.
B2) OPERATION (Automatic / Step-step):
The default settings of the control unit have “Automatic”
operating logic. If you want to select “Step-Step” operating
mode, proceed as follows: set SEL and SET to display
B2
then
press SET to select the function. At the same time
DOT 1
will
start to flash, press SET to change the function,
DOT 2
will
remain permanently lit and the operation will be complete.
Repeat the procedure to restore the previous configuration.
B3) WATER HAMMER:
The control unit is supplied by the manufacturer with Water
Hammer disabled. If you want to enable the Water Hammer
function at maximum power, proceed as follows: set SEL and
SET to display
B3
then press SET to select the function. At the
same time
DOT 1
will start to flash, press SET to change the
function,
DOT 2
will remain permanently lit and the operation
will be complete.
If, however, you want to enable the Water Hammer function
with the force set via trimmer VR2, proceed as follows: set SEL
and SET to display
B3
then press SET to select the function. At
the same time
DOT 1
will start to flash, press SET and at the
same time
DOT 1
will start to flash quickly, press SET to
change the function,
DOT 2
will remain permanently lit and the
operation will be complete.
Repeat the operation to restore the initial configuration.
Accordingly, we can facilitate the release of the gate and
therefore allow the proper execution of the opening phase. In
fact, the control unit, before starting the opening phase sends a
closing command for 2 seconds with power relative to the
choice selected.