GENERAL INFORMATION
NOTICE:
Model Number of your pump is located on the
pump shell. Record this number and keep in a safe place for
future reference in the event service is needed.
The most important things you should know about your well
are: (1) its total depth; (2) depth to water; (3) draw down
water level.
1. The well
total depth
is the distance from the ground
level to the well bottom.
2.
Depth to water
is measured from the ground level to the
water level in the well when the pump is not running.
3.
Draw down water level
is the distance from ground
level to the water level while water is being pumped. In
most wells, the water level drops when water is being
pumped.
Usually you can obtain this information from your well
driller. Enter it in box at right.
3
Record the following information at the
time of installation and retain it for future
reference:
Pump Model No.
Control Center Model No.
Horsepower
Volts
Phase
Hertz
Full Load Amps
Well Casing Diameter
Well Depth
Depth to Water
Draw Down Water Level
Table I - Pump Performance Chart (In Gallons Per Minute)
Residential Pumps with 1-1/4” Discharge
Discharge
Model
Pressure
Pumping Depth in Feet *
Number
H.P.
Voltage Stages
P.S.I.
20
40
60
80
100
125
150
175
200
250
300
350
400
390.285510
1/2
115
6
40
13.6
12.6
11.5
10.1
8.6
–
–
–
–
–
–
–
–
390.285520
1/2
230
6
40
13.6
12.6
11.5
10.1
8.6
–
–
–
–
–
–
–
–
390.284020
1/2
230
6
40
13.6
12.6
11.5
10.1
8.6
–
–
–
–
–
–
–
–
390.285530
3/4
230
8
40
–
–
13.5
12.7
11.9
10.7
9.4
7.9
–
–
–
–
–
390.284030
3/4
230
8
40
–
–
13.5
12.7
11.9
10.7
9.4
7.9
–
–
–
–
–
390.284040
1
230
10
40
–
–
–
–
13.5
12.9
11.9
10.9
9.8
7.4
–
–
–
390.284050
1-1/2
230
14
40
–
–
–
–
–
–
–
13.5
12.9
11.7
10.4
8.9
7.1
High Capacity Pumps with 1-1/4” Discharge
Discharge
Model
Pressure
Pumping Depth in Feet *
Number
H.P.
Voltage Stages
P.S.I.
20
40
60
80
100
125
150
175
200
250
300
350
400
390.284060
1
230
7
40
26.4
24.7
22.7
20.7
18.4
–
–
–
–
–
–
–
–
390.284070
1-1/2
230
9
40
–
–
25.8
24.3
22.9
21.0
18.8
15.4
–
–
–
–
–
390.284080
2
230
12
40
–
–
–
–
26.4
25.1
23.7
22.2
20.8
17.2
–
–
–
390.284090
3
230
17
40
–
–
–
–
–
–
–
26.7
25.5
23.8
21.7
19.6
16.8
Pump
Control
Max
Fuse
AWG Cable Size
Model
Box
Load
Rating
No.
Type
No.
HP
Volts
Amps
(Amps)
12
10
8
390.285510
2-Wire
–
1/2
115
12.0
20
160
–
–
390.285520
2-Wire
–
1/2
230
6.0
15
650
1020
–
390.285530
2-Wire
–
3/4
230
8.4
15
480
760
–
390.284020
3-Wire
390.284120
1/2
230
6.0
15
650
1020
–
390.284030
3-Wire
390.284130
3/4
230
8.4
20
480
760
–
390.284040
3-Wire
390.284140
1
230
9.8
25
400
630
–
390.284060
3-Wire
390.284140
1
230
9.8
25
400
630
–
390.284050
3-Wire
390.284250
1-1/2
230
11.5
30
310
480
770
390.284070
3-Wire
390.284250
1-1/2
230
11.5
30
310
480
770
390.284080
3-Wire
390.284260
2
230
13.2
30
250
390
620
390.284090
3-Wire
390.284270
3
230
17.0
45
190
300
470
Max. Cable
Length in Feet –
Disconnect
switch to motor
}
}
Max. Cable
Length in Feet –
Disconnect
switch to motor
*Pumping depth in feet is the maximum distance to water from ground level. This maximum distance (drawdown water level) occurs while pump is operating.
In most cases, when pump is not running, the water level will rise to a higher point in the well.
TABLE II - Fusing, Wiring and Cable Selection (Copper Conductors Only)