INSTALLATION
If depth of well and the distance to the water level in the
well are not known, proceed as follows:
1. Tie an object that will float to the end of a ball of string and
drop it into the well.
2. When float hits water and string becomes slack, mark the
string and pull float from well. Measure distance between
mark and float for the water level in the well.
3. Remove float, replace with a heavy object that will sink in
water and drop it into the well until string becomes slack.
Mark string and pull object from well.
4. Measure distance between mark and object for depth of
well.
If drawdown water level is not known, set pump 5 feet from
the bottom of the well.
Basic Tools and Materials Needed
Study Figures 1 thru 3. Figure 1 shows the piping and elec-
trical connections of a submersible pump in a well. Figure 2
shows typical installation of a Sears Captive Air® Tank
System. Figure 3 shows typical installations of a Sears
Standard Air Tank System. These illustrations will help you
determine what materials you will need for piping.
Plastic Pipe Installation
Tools: Knife, Wire Cutters, Pliers, Screwdriver, Hammer,
Adjustable Wrench, Hacksaw, Pipe Wrenches (2).
4
Standard Air Tank Installation
Captive Air Tank Installation
®
Power
Cable
Power
Cable
Nylon
Tape
Nylon
Tape
Safety
Rope
Well Seal
(Purchase
Locally)
Conduit or
Sleeve
Cable
Splices
Plastic
Pipe
Adapter*
Plastic Pipe
Adapter*
Pump
Check
Valve
Torque
Arrester
(Purchase
Locally)
Centering
Guide
1178 0794
* Plastic pipe adapter, pipe
clamps, and torque arrester
used only with plastic pipe.
Splice Cables
Like This – Not Like This
4"
2 Ft.
Galvanized
Pipe up
through well
seal
Pipe Tee
with Plug
Plastic Pipe
Adapter
Pipe
Clamps*
Power
Cable
Nylon
Tape
Safety
Rope
Well Seal
(Purchase
Locally)
Conduit or
Sleeve
Cable
Splices
Plastic
Pipe
Adapter*
Pump
Bleeder
Orificies
Check
Valve
Centering
Guide
Torque
Arrester
(Purchase
Locally)
3 Ft.
To Tank
To Tank
2 Ft.
Plastic Pipe
Adapter
3 Ft.
Pitless
Adapter
Electrical
Service
To Tank
Pitless
Adapter
Electrical
Service
Vent
Sanitary Well Seal
Pitless Adapter
Sanitary Well Seal
Pitless Adapter
Galvanized
Pipe
Galvanized
Pipe
Figure 1: Typical Well Pipe Installations
Pressure
Relief Valve
Stock No. 2720
Pressure
Switch
Stock
No. 2782
Pressure Gauge
Stock No. 2768
Submersible
Pump Manifold Kit
Stock No. 27221
958 0594
To Service
To Pump
Motor
Electrical
Disconnect
Box
Control
Center*
From
Well
12"
Max.
959 0594
To
Service
To Pump
Motor
Electrical
Disconnect
Box
Control
Center*
From
Well
12"
Max.
963 0594
Gate
Valve
Union
Air
Volume
Control
Figure 2: Captive-Air
®
Pressure Tank Installation
Figure 3: Standard Pressure Tank Installation
† NOTICE: Control Center is used with 3-wire pumps
only. For 2-wire pumps, run cable directly from pres-
sure switch to motor.
Manifold
Detail