background image

• 7 •

smart cable. When the condition is corrected, the smart cable will 

automatically reset.

7.  After a proper connection has been made, crank the engine. If the engine 

does not start within 5-8 seconds, stop cranking and wait at least 1 minute 

before attempting to start the vehicle again.  

nOTE: If the car does not crank a second time, check the smart cable to 

see if the green LED is lit. If an LED is flashing, refer to the information on 

the back of the smart cable and note which error code is in effect. When 

the condition is corrected, the smart cable will automatically reset.

nOTE: Cold weather may affect the performance of the jump starter’s 

lithium battery. If you hear only a click and the engine does not turn 

over, try the following:

With the jump starter connected to the car battery and the green 

LED illuminated on the smart cable, turn on all lights and electrical 

accessories for one minute. This draws current from the jump starter 

and warms the battery. Now try to crank the engine. If it does not turn 

over, repeat the procedure. Extremely cold weather may require two or 

three battery warmings before the engine will start.

iMPORTAnT: DO NOT attempt to jump start your vehicle more 

than three consecutive times. If the vehicle will not start after three 

attempts, consult a service technician.

8.  After the engine starts, unplug the battery clamps from the jump starter 

socket and then disconnect the black clamp (-) and the red clamp (+), in 

that order. Slide the ON/OFF switch to the OFF position.

9.  Recharge the unit as soon as possible after each use.

8.2  ChARging A MOBilE DEViCE, Using ThE UsB PORTs

The SL65S Includes two USB ports. One provides up to 2.1A at 5V DC, the 

other provides up to 1A at 5V DC. 

1.  Consult your mobile device manufacturer for proper charging power 

specifications. Connect a mobile device cable to the appropriate USB port. 

2.  Slide the ON/OFF switch to the ON position. Charging should begin 

automatically. The display will show which port is in use.

3.  Charging time will vary, based on the mobile device’s battery size and the 

charging port used.

nOTE: Most devices will charge with either USB port, but may charge 

at a slower rate. 

4.  When finished using the USB port, disconnect the charging cable from 

your mobile device and then disconnect the charging cable from the unit. 

Slide the ON/OFF switch to the OFF position.

5.  Recharge the unit as soon as possible after each use.

NoTe:

 If no USB device is connected, power to the USB ports will 

automatically shut off after 30 seconds. 

8.3  Using ThE lED lighT

1.  Slide the ON/OFF switch to the ON position.

2.  Hold down the display   button for 3 seconds.

3.  Once the LED light is on, press and release the display   button to cycle 

through the following modes:

• Steady glow

• Flash for an SOS signal

Summary of Contents for SL65S.V2

Page 1: ...Model SL65S V2 Jump Starter OWNER S MANUAL Original Language Version Jack Sealey Limited SL65S V2 Issue 1 08 12 17 ...

Page 2: ...e of an attachment not recommended or sold by Sealey for the SL65S may result in a risk of fire electric shock or injury to persons or damage to property 1 8 To reduce the risk of damage to the electric plug or cord pull by the adaptor rather than the cord when disconnecting the unit 1 9 Do not operate the unit with damaged cables or clamps 1 10 Do not operate the unit if it has received a sharp b...

Page 3: ...work near a lead acid battery 2 7 Have plenty of fresh water soap and baking soda nearby for use in case battery acid contacts your eyes skin or clothing 2 8 Wear complete eye and body protection including safety goggles and protective clothing Avoid touching your eyes while working near the battery 2 9 If battery acid contacts your skin or clothing immediately wash the area with soap and water If...

Page 4: ... the metal part of the battery clips or cut the insulation of the cables 4 3 Stay clear of fan blades belts pulleys and other parts that can cause injury 4 4 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 4 5 Determine which post of the battery is grounded connected to the chassis If the negative post is grounded t...

Page 5: ...harged internal battery will read 100 Charge the internal battery if the display shows it is under 85 2 To reduce the risk of electric shock unplug the USB charging cable from the outlet before attempting any maintenance or cleaning Simply turning off the controls will not reduce this risk 3 When charging the internal battery work in a well ventilated area and do not restrict the ventilation in an...

Page 6: ...e s electrical system NOTE The internal battery must have a charge if at least 40 to jump start a vehicle 1 Turn the ignition OFF 2 Lay the DC cables away from any fan blades belts pulleys and other moving parts Make sure all of the vehicle s electrical devices are turned off 3 For a negative grounded vehicle connect the POSITIVE RED clamp from the jump starter to the POSITIVE POS P ungrounded pos...

Page 7: ...nsult a service technician 8 After the engine starts unplug the battery clamps from the jump starter socket and then disconnect the black clamp and the red clamp in that order Slide the ON OFF switch to the OFF position 9 Recharge the unit as soon as possible after each use 8 2 CHARGING A MOBILE DEVICE USING THE USB PORTS The SL65S Includes two USB ports One provides up to 2 1Aat 5V DC the other p...

Page 8: ... Never completely discharge the battery 4 Charge after each use 5 Charge at least once every month if not in frequent use to prevent over discharge 11 TROUBLESHOOTING PROBLEM SOLUTION The jump starter s display will not turn on Make sure the unit is charged Connect to a power source to reset Make sure the ON OFF switch is set to the ON position The thermometer symbol is flashing The unit is too ho...

Page 9: ...ed LED flashes four times Low voltage protection Red LED flashes five times High temperature protection Red LED lit solid OK to press button to jump start 12 SPECIFICATIONS Internal battery type Lithium ion polymer Capacity 8 000 mAh 29 6 Wh USB output 5V DC 2 1A 1A Jump start 600A peak 300A cranking Charging temperature 0 50 C 13 DISPOSAL INFORMATION 13 1 Internal Battery The battery must be remo...

Page 10: ...sales sealey co uk or telephone 01284 757500 Weee Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Environment Protection Recycle ...