SCSI Commands
Page
61
3
Reserved
4
Extended POST Mode
5
Inquiry String Control
6
Firmware Test Control
7
Data Compression Control
8
Auto-Unload Mode
Field Descriptions
Field
Bytes
Bits
Description
Page Code
0
0-5
21h, indicating the Drive Capabilities Control Mode Page.
Additional
Page Length
1
07h, indicating that seven parameter bytes follow the Page Length
byte.
Operating
Systems
Support
2
0 = Standard LTO (default AU1-SCSI and ISV)
POST Mode
4
0 = Enable POST (default)
1 = Disable POST
Inquiry String
Control
5
0 = Standard Seagate Viper Inquiry string (default)
1 = Factory test only Inquiry string 1
2 = Factory test only Inquiry string 2
Firmware
Test Control
6
0 = disable Factory test mode code (default)
1 = enable Factory test code 1
2 = enable Factory test code 2
Data Com-
pression
Control
7
0 = Full Mode Page 0Fh & 10h Control of Compression (default)
1 = Auto compression with No SCSI Mode control
2 = Compression Disabled with No SCSI Mode control
Auto Unload
Mode
8
The Auto Unload Mode allows the drive to control how the tape is
unloaded when (a) a power cycle occurs with a tape inside, (b) an
incompatible tape is inserted, (c) a firmware download occurs with
a tape inside, and (d) the cleaning tape has finished the cleaning
process.
0 = Stay at BOT or SEATED; do not unthread and do not unload.
(default)
1 = Unthread.
2 = Unthread and unload.
Reserved
All reserved bits must be 0.
Interface Control Mode Page
The Interface Control mode page controls the selection ID used by the primary
interface (SCSI Parallel or Fibre Channel), as well as parameters of the Library serial
interface. A single copy of this page is maintained for all initiators. New CmdFwd and
Alerts will be in effect immediately after Mode Select. New Baud Rate, 2StopBits,
Next Selection ID, Target Initiated Bus Control, and Disable Wide Bus Mode will be
in effect the next reset or power cycle after Mode Select. This page persists across
power cycles.
Alerts are not implemented, so this field has a value of 0 and is not changeable.
Byte
Bits
7
6
5
4
3
2
1
0
0
Reserved
Page Code (22h)
1
Page Length (0Eh)
2
Baud Rate