All parameters are one byte long. Each parameter is either zero to indicate the
corresponding condition has not occurred or one to indicate that the corresponding
condition has occurred. The log page is used in conjunction with Information
Exceptions Mode Page (1Ch) that controls the action taken by the drive when a flag
is set and sets various other control mechanisms of the Tape Alert system. A flag is
set whenever the condition for setting the flag exists. There are three types of flags,
Informational, Warning, and Critical. The type of flag depends upon the severity of
the condition that sets the flag. Flags are cleared on the following conditions:
•
At drive power on
•
When the TapeAlert Log page is read
•
When specified corrective action has been taken (such as using a cleaning
cartridge)
•
On a SCSI bus reset or bus device reset message
•
On Log Select reset (note that the recommended action on receiving Log Select
for the TapeAlert Log page is to reject the command with an error).
Additional information regarding the Tape Alert system is found in the SCSI-3 Stream
Commands (SSC) Standard and Tape Alert specification. The following is the list of
flags (parameters) supported by the drive.
Parameter
Description
Type
Length
3
Hard Error
Warning
1
9
Write Protect
Critical
1
11
Cleaning media in drive
Informational
1
14
Unrecoverable snapped tape
Critical
1
15
Memory in Cartridge Failure
Warning
1
16
Forced Eject
Critical
1
17
Read Only Format
Warning
1
18
Tape Directory Corrupted on Load
Warning
1
20
Clean now
Critical
1
21
Clean periodic
Warning
1
22
Expired cleaning media
Critical
1
23
Invalid cleaning tape
Critical
1
30
Hardware A
Critical
1
31
Hardware B
Critical
1
32
Interface
Warning
1
34
Download Fault
Warning
1
51
Tape Directory Invalid at Unload
Warning
1
Tape Usage Log (30h)
The Tape Usage Log Page returns information about the current tape cartridge.
These values are all read directly from the tape log. The Page Control, PC, field is
ignored and accumulated values are always returned.
Page Code
Page Length
30h
5Ah
Parameter
Description
Length
1
Thread Count
4