Occurrences of this are extremely rare and are usually a result of Voltage Spikes or strong Electro-Magnetic 
Interferences. 
 
The Device may also be reset by depressing the Black reset Button on the Circuit Board. This does not effect any of the 
overall operation of the VMC; it purely pulls the device back as if it were initially powered up. The only information lost on 
pressing the Black Button is the following: 
 
 

1. Any Credit on the display will be cleared 

 

2. Any error Codes that occurred are cleared. 

 
Summary Of Software Versions 
 
Motor Version Numbers 
Ver 

1 2 3 4 5 6 FLASH 

TAS 

NOTES 

      DATE 

1.00 

 

 

 

 

 

 

 

 

 

Dec ‘03 

1.01 

    X 

 

extension of column empty check

 Feb 

’04 

 

1.02 

    X 

Extension of column empty check & Countdown on vend    

Mar  ‘04 

1.03 

    X 

Improved motor handling, shortened timing value 

Jun ‘04 

 
**.:     Includes 00—07 minor device changes 
TAS:  Token Access System 
ACC: Accumulated Audit Readings 
 

SOLD OUT FEATURE 

 
After pressing the button and if there is no can in any/all four selections, the Display will show ‘SOLD OUT’. However 
other the other selections can be made as usual. 

Note:

 DISPLAY may also show ‘SOLD OUT’ in case motor is not in home position or if the motor is faulty. 

 

Section 3  

 

 

 

       MONEY MECHANISM

 

 

COIN VALIDATOR 

 

The Coin Validator receives the coin from customers. The Coin Validator will accept quarters, dimes, and nickels, and can 
be set to accept the new golden dollar. For (F) series of Vendors the Coin Validator will be preset to accept U.K. and Euro 
coins. 
One (1) coin box is provided with your vendor, it is stored in the bottom of the vertical shelf. Once the front door is opened, 
pull out the coin box to empty it. 

             

 

CLEANING 

 

Your Coin Validator needs to be cleaned only when the Coin Validator no longer reads the coin values. 
1. Cleaning the Optics. You will need cotton swabs, and a mild soap and water solution. 

a.  Unlock and open the front door 
b.  Remove the Coin Box, and Pull the Vertical shelf out. 
c.  Swab the lenses with the solution, and reassemble. 

 

VERTICAL SHELF REMOVAL 

 

To Remove the Vertical Shelf 

a.  Unlock and open the Front door, unplug the Vendor 
b.  Slide out the Vertical Shelf completely 
c.  Disconnect wiring harness 

d. 

Unscrew the two screws holding the vertical shelf using allen key at top right side of the shelf. (Fig. 5)

 

e.  Remove the vertical shelf. (Fig. 5) 

 

Fig.5

 

Summary of Contents for Space Saver Series

Page 1: ...1 Space Saver Series Table Top Soda Vendor Operator s Manual...

Page 2: ...nt of any parts of the equipment which shall within one year of the date of shipment to the original purchase be demonstrated to be defective The original purchaser may obtain repair or replacement of...

Page 3: ...of your SS series Beverage Vendor Fig 1 HOW TO LOCK UNLOCK THE DOOR OF VENDOR Your Beverage Vendor has 2 locks To open the door unlock the right side lock by turning the key clockwise Thereafter open...

Page 4: ...isplay Fig 3 This means that your customers will see actual cans of the product your vendor is offering 1 Set Up of Live display a Unlock and open the front door b Load product display shelf to corres...

Page 5: ...UDIT Displays Au Pressing Red Button PRICE SETTING Displays PS Pressing Red Button COIN VALUE SETTING Displays Cn Pressing Red Button CONTROL WORD SETTING Displays Ct Where is current word Pressing Re...

Page 6: ...rvice Button to scroll to exit or press Reject Button to exit Notes Prices may be set from 00 01 to 99 99 depending upon coin values It is not possible to set a zero price The default price setting is...

Page 7: ...Credit Carried Forward for 60 sec 06 X X X FREE VEND NO CREDIT REQUIRED None 07 X X X TEST VEND NO CREDIT REQUIRED None Press the red service button repeatedly until Displays Ct where is current valu...

Page 8: ...or Seaga 3 Wire Motor 12V gray Open Yes Individual 3 Reserved 4 Reserved 5 Reserved 6 Reserved Operation How to set up your Motor Version To change do the following 1 Press the Red Service Button till...

Page 9: ...The VMC constantly tests the operation of the machine the data stored and the peripherals attached Every 01 seconds a self test analysis is done to verify correct operation of the machine Further test...

Page 10: ...signment 1 Service Code AS 1 Press the Red Service Button to enter Application Mode Displays Ap You are now in application mode 2 Press and hold selection 2 for seconds till Displays set The machine w...

Page 11: ...Exit Service Mode 49 Coin Validator alarm Possible fraud on Coin acceptor Check operation of Coin Acceptor 51 Battery Low Replace Battery Exit Service Mode Press any selection button 5 times 52 Coin...

Page 12: ...er selections can be made as usual Note DISPLAY may also show SOLD OUT in case motor is not in home position or if the motor is faulty Section 3 MONEY MECHANISM COIN VALIDATOR The Coin Validator recei...

Page 13: ...f the triangle flap will come in contact with the bottom product tray creating an anti theft wall to act as a block Q In the event of a power outage will I have to reprogram my Vendor A No Your select...

Page 14: ...re filled in to the vendor The door and the vending flaps of the can unit can be dislodged from the can unit by removing two screws use allen key no 5 which are located on either side of the machine b...

Page 15: ...15 and then load 1 can in 3rd shelf step 2 fill the bottom shelf completely step 3 Now Load 1 can in 2 nd shelf step 4 Load 3rd shelf completely step 5...

Page 16: ...So when a fresh stock of cans are loaded usually from the upper shelves it is likely that the lower shelves of the can unit may still be holding some older cans for an interval of time Although bever...

Page 17: ...sily accessed by opening two screws located on the front bottom panel of the vendor Remove the two screws at the mid point of the Panel Fig 8 The refrigeration Deck can now be pulled out from the vend...

Page 18: ...depend upon your local climate CLEANING THE CONDENSER Dust and dirt restricts good airflow and cooling of the condenser due to which the refrigeration unit will not chill the cans properly Remove the...

Reviews: