background image

Rev. 2012.02.27 

12

    

Note

 

a). Safety Feature : Button B will only be operational from the moment that any of the Negative Counters have 
      reached to zero value. 

       

        If none of the neg. counters are zero, then pressing button no. B     will not yield any results. 

 
b). To prevent accidental partial resetting, button no. B needs to be kept pressed for 3-4 seconds, till the display shows 
r-ld, confirming the partial resetting has been executed.

 

 
5. All Reset Feature: If it is desired to totally reset all the shelves, irrespective of whether any of them have reached 
zero value, then button no. A needs to be kept pressed for 3-4 seconds.

 

 
 A long beep with 

ALL r-ld

, on display will confirm that the  resetting/reloading of all the 5 Negative Counters to their 

preset value has taken place 

 
 

      

Note

 :  

 

a) 

To avoid accidental  reloading of all the neg. counters, button no. A (fig.2) needs to be pressed for 3-4 seconds, till 
the display shows ALL r-ld, thereby confirming the reloading of all Negative Counters. 

 
b) 

It is desirable to indicate on an Instruction label on the front of the machine that the customer should first press the 
selection button on the machine to check product availability before inserting money into the coin validator.

 

 

If money is first inserted into the validator and all the shelf selections are empty i.e. ‘Sold Out’

 

and then a selection is 

made, then the display will show ‘Sold Out’ and the money will not be returned.

 

 

 

Test Sequence 

The VMC constantly tests the operation of the machine, the data stored and the peripherals attached. Every .01 
seconds, a self-test analysis is done to verify correct operation of the machine. Further tests are done on Power Up, 
Button Press, Coin Insertion and entering/exiting Service mode. These tests will  generate the relevant fault code as 
necessary. However, it is possible to do a thorough analysis through Service Code AP, which will individually test each 
motor as well as escrows and other related functions. This is useful to re-align any jammed motors. 
 

Test Code Map

 

 
 

 

TEST 

WHAT IS VISIBLE 

  ACTION 


Escrow Return 
Power 

Displays  ’ TEST’ 
 

Escrow Return Opens [if present] 
Power Status Checked 


LEDS 
Price Setting 

Displays ‘ 88.88 ‘ all Column LEDS on 

Ensure all LED Segments Illuminate 
Confirm Prices are set 


Escrow Keep 

Displays PL.** [Timing Value] 

Escrow Keep Opens [if present] 
Confirms Coin Values 


Motor 1 
Control word 

Displays 01.-* where * is motor Version 

Motor 1 operates [if present] 
Confirms that a valid control word is set 


10 

Motor 2 
Motor Assignment 

Displays 02.-* where * is motor Version 

Motor 2 operates [if present] 
Confirms that a valid motor assignment is set 

11 
12 

Motor 3 
Coin count value 

Displays 03.-* where * is motor Version 

Motor 3 operates 
Confirm that a valid coin count value is set 

13 
14 

Motor 4 
Audit 

Displays 04.-* where * is motor Version 
 

Motor 4 operates [if present] 
Confirms that all audit registers are valid 

15 
16 

Motor 5 
Timing belt 

Displays 05.-* where * is motor Version 

Motor 5 operates [if present] 
Confirms that valid timing belt value is set 

17  End of Test 

Displays 0-.** 

Where ** is a fault found during test 

 
 
1. Press the Red Service Button to Enter Service Mode to scroll to  

Displays 

AP.– 

 

You are now in applications Mode 

2. Press Selection 1 to activate test sequence 

 

 

 

Displays 

test 

 

The machine will now perform a test as outlined below any faults that occurred will be indicated  

Summary of Contents for SL5000

Page 1: ...Rev 2012 02 27 1 SL5000 Operator s Manual...

Page 2: ...n this process It is important that you keep the original packaging for your vending machine at least through the warranty period If your machine needs to be returned for repair you may have to purcha...

Page 3: ...M The delivery system of your SL5000 incorporates a Selection Pad an LCD Display and helix coils The customer inserts money into the coin slot and enters their selection on the Selection Pad the selec...

Page 4: ...0 seconds When the machine goes to sleep the following messages are displayed under set conditions When Awake When Asleep i 00 00 09 00 0 00 9 99 Decimal points always on ii 10 00 99 99 10 00 99 99 De...

Page 5: ...goes to Sleep 3 Service Mode can be exited by stepping through all the menu options using the Service Button or automatically if there is no activity for 30 seconds On Exit the software version numbe...

Page 6: ...ammed 4 Insert additional coins if required and repeat for other selections 5 Press Service Button to scroll to exit Prices may be set from 00 00 to 99 99 depending upon coin values The default price...

Page 7: ...nd Price Held until power removed Returned when ER pressed or held until power removed 05 Credit Vend Price Held for 60 seconds Returned when ER pressed or held for 60 seconds 06 None Free Vend Mode N...

Page 8: ...til Displays tE 2 Press Service Button to exit In Test Mode pressing a selection switch will operate the selected motor If a coin is inserted its value will be displayed for 1 second ALL MOTORS MODE 1...

Page 9: ...d Replace the battery 73 Battery nearly low Warning Replace recharge the battery soon Soft Errors unit will continue to operate though failed motors will show as Sold Out and be blocked from operation...

Page 10: ...t so an approximate setting of the timing value needs to be set The vend cycle is the time from motor start when at home to motor end return to Home in seconds This translates directly to the timing v...

Page 11: ...as been selected and the represents the current value of the Negative Counter that has been assigned to that shelf is displayed in scrolling mode from shelf 1 to 5 3 Sold out Feature After setting the...

Page 12: ...done to verify correct operation of the machine Further tests are done on Power Up Button Press Coin Insertion and entering exiting Service mode These tests will generate the relevant fault code as n...

Page 13: ...lection 2 for seconds till Displays set The machine will automatically exit from service mode and display Out Of Ord e r 3 Press Red Service Button to re enter Service Mode and re configure settings F...

Page 14: ...ce Exit Service Mode 62 Escrow Return Time out Check Escrow unit Activate Test Sequence Exit Service Mode 70 EEPROM Write Error Check Prices and Coin data 71 EEPROM Read Error Check Prices and Coin da...

Page 15: ...ution and reassemble COMMON QUESTIONS AND ANSWERS Q How High Can I set my Prices A Each selection can be priced individually up to 99 99 Q Can Customers reach down and help themselves to product A No...

Page 16: ...service repair alteration or disassembly has been performed Any defects caused by improper power source poor water quality or pressure an installed water filtration system not fully functioning abuse...

Reviews: