Seaga SL5000 Operator'S Manual Download Page 13

Rev. 2012.02.27 

13

by a 2 digit code at the end of the Test Sequence.

   Displays  Er.** 

 

where ** may be a 2 digit code 

3. Press Red Service Button to exit or Press Reject Button to exit. 
 

Notes:

  

- The test sequence may activate a motor for two cycles; this is normal. 

 

- If after a test a fault code appears, correct the fault and test again. 

 

- The Display will return Normal Mode 60 seconds after the last button has been pressed unless  
  the Red Service has been pressed or the reject is pressed.

 

 

FACTORY DEFAULT SETTING 

 

The SL5000 can be reverted back to factory defaults by the user by entering service code AP.-- Care must be taken 
while doing this as all data will be lost and will have to be entered again. 
 
A list of factory defaults is as follows: 

 

DATA 

DEFAULT VALUE 

TO CHANGE 

 

 

 

Standard Audit Totals 

0000.00 

 

Prices 

Factory set 

Service Code PS 

Coin Value Settings 

Factory set 

Service Code Cn 

Coin Count Value 

15  [if escrow present] 
99  [if no escrow present] 

Service Code Cn 

Credit [Display] 

00.00 

 

Control Word 

5 [excess credit carried forward for 60 seconds] 

Service Code Ct 

Motor Version 

Version 2 [all motors] 

Service Code AS 

Motor Timing Value  

Service Code  AS 

Motor Assignment 

Selection 1 – Motor 1 etc 

Service Code AS 

Motor Backup 

No-Individual Assignment (1) 

Service Code AS 

Negative Counter  

  Factory set 

 

 

 

1. Press the Red Service Button to enter Application Mode 

 

Displays 

Ap.- 

 

 

You are now in application mode 

2. Press and hold selection 2 for seconds till  

 

 

 

Displays 

set 

 

 

The machine will automatically exit from service mode and display ‘ Out Of Ord(e)r ‘ 

3.    Press Red Service Button to re-enter Service Mode and re-configure settings.

 

 

Fault Analysis

 

Within the machine there is an internal fault analysis. Every 0.1 second the machine will do a self analysis test. This 
test does not affect the normal operation of the machine. There will be no change of status of the machine from a 
users point of view. The machine will still accept coins, display prices and vend products even during self-analysis test. 
If the machine observes a problem it will double verify the cause and store the error, which will be displayed during 
service mode. To display an error code, simply enter service mode by pressing the red button. The error code will be 
displayed intermittently. To clear an error code, simply exit service mode (rectify error if necessary). 
 
Note: If more than 5 normal error codes have been detected the machine will assume ‘Fatal error’ status putting the 
machine ‘Out of Ord(e)r’. 
 
 

Fault Code Map 

Code Description   

 

 

Remedy 

 

-- 

No error present 

 

None 

00 

Empty Error Location 

  

None 

01 

Motor 1 Error 

 

 

Remove Jam-Activate Test Sequence-Exit Service Mode 

02 

Motor 2 Error 

 

 

Remove Jam-Activate Test Sequence-Exit Service Mode 

03 

Motor 3 Error 

 

 

Remove Jam-Activate Test Sequence-Exit Service Mode 

04 

Motor 4 Error 

 

 

Remove Jam-Activate Test Sequence-Exit Service Mode 

05 

Motor 5 Error 

 

 

Remove Jam-Activate Test Sequence-Exit Service Mode 

30 

Zero Price Setting 

 

Reset all prices - Exit Service Mode 

31 

Zero Coin Count Value   

Reset Coin Count Value - Exit Service Mode 

Summary of Contents for SL5000

Page 1: ...Rev 2012 02 27 1 SL5000 Operator s Manual...

Page 2: ...n this process It is important that you keep the original packaging for your vending machine at least through the warranty period If your machine needs to be returned for repair you may have to purcha...

Page 3: ...M The delivery system of your SL5000 incorporates a Selection Pad an LCD Display and helix coils The customer inserts money into the coin slot and enters their selection on the Selection Pad the selec...

Page 4: ...0 seconds When the machine goes to sleep the following messages are displayed under set conditions When Awake When Asleep i 00 00 09 00 0 00 9 99 Decimal points always on ii 10 00 99 99 10 00 99 99 De...

Page 5: ...goes to Sleep 3 Service Mode can be exited by stepping through all the menu options using the Service Button or automatically if there is no activity for 30 seconds On Exit the software version numbe...

Page 6: ...ammed 4 Insert additional coins if required and repeat for other selections 5 Press Service Button to scroll to exit Prices may be set from 00 00 to 99 99 depending upon coin values The default price...

Page 7: ...nd Price Held until power removed Returned when ER pressed or held until power removed 05 Credit Vend Price Held for 60 seconds Returned when ER pressed or held for 60 seconds 06 None Free Vend Mode N...

Page 8: ...til Displays tE 2 Press Service Button to exit In Test Mode pressing a selection switch will operate the selected motor If a coin is inserted its value will be displayed for 1 second ALL MOTORS MODE 1...

Page 9: ...d Replace the battery 73 Battery nearly low Warning Replace recharge the battery soon Soft Errors unit will continue to operate though failed motors will show as Sold Out and be blocked from operation...

Page 10: ...t so an approximate setting of the timing value needs to be set The vend cycle is the time from motor start when at home to motor end return to Home in seconds This translates directly to the timing v...

Page 11: ...as been selected and the represents the current value of the Negative Counter that has been assigned to that shelf is displayed in scrolling mode from shelf 1 to 5 3 Sold out Feature After setting the...

Page 12: ...done to verify correct operation of the machine Further tests are done on Power Up Button Press Coin Insertion and entering exiting Service mode These tests will generate the relevant fault code as n...

Page 13: ...lection 2 for seconds till Displays set The machine will automatically exit from service mode and display Out Of Ord e r 3 Press Red Service Button to re enter Service Mode and re configure settings F...

Page 14: ...ce Exit Service Mode 62 Escrow Return Time out Check Escrow unit Activate Test Sequence Exit Service Mode 70 EEPROM Write Error Check Prices and Coin data 71 EEPROM Read Error Check Prices and Coin da...

Page 15: ...ution and reassemble COMMON QUESTIONS AND ANSWERS Q How High Can I set my Prices A Each selection can be priced individually up to 99 99 Q Can Customers reach down and help themselves to product A No...

Page 16: ...service repair alteration or disassembly has been performed Any defects caused by improper power source poor water quality or pressure an installed water filtration system not fully functioning abuse...

Reviews: