background image

Rev. 2012.02.27 

4

BATTERY MODE OF OPERATION 

During Battery mode, the machine operates in ‘Sleep Mode’. This means that when the machine is not in operation 
(between vends), it will automatically shut down in order to save battery power, thus prolonging the life of the battery. 
During ‘Sleep Mode’ the machine display turns off its left hand digit (unless there is a value greater than 0 present) and 
the machine monitors to see if a coin has been inserted or a button pressed in order to ‘wake-up’. The following 
conditions will ‘wake-up’ the machine from ‘Sleep Mode’. 
 
1. Coin Insertion 
2. Selection Button Press 
3. Black (Reset) Button Press 
4. Red Service Button Press 
 
On Wake-up the machine will only go back to ‘Sleep Mode ‘ under the following conditions: 
 
  1. Directly after a vend has been made (Unless there is excess credit present in which case  
      the machine will wait a further 60 seconds before going to sleep]. 
  2. After 30 seconds after a selection has been pressed and the machine contains product. 
  3. After 20 seconds after a selection has been pressed and the machine does not contain a   
      product. 
  4. After 5 seconds if an invalidated coin has been inserted and the machine contains product. 
  5. After 60 seconds after a coin has been inserted and validated. 
  6. After 5 seconds if the machine is completely empty. 
  7. After 5 seconds after if the machine is out of order. 
  8. After 5 seconds after the black (reset) button is pressed and the machine is empty. 
  9. After 20 seconds after the black (reset) button is pressed and the machine contains product. 
10. After 8 seconds after leaving service mode 
 
These values are extended each time a selection is pressed or coin is inserted to a maximum of 60 seconds. 
When the machine goes to sleep, the following messages are displayed under set conditions 
 
 When 

Awake 

     When 

Asleep 

i. 

00.00 – 09.00   

 

 

 

  0.00 – 9.99 

 (Decimal points always on) 

ii. 

10.00 – 99.99   

 

 

 

10.00 – 99.99    (Decimal points always on) 

iii. 

Free 

     Fr.ee 

  

(Decimal 

points 

always 

on) 

iv. 

Test 

     Te.st 

  

(Decimal 

points 

always 

on) 

v. 

Out 

of 

Ordr 

    F-Er 

  

(Fatal 

Error 

set) 

vi. 

- - .- -   

 

 

 

 

-.- - 

 

 (Decimal point always on) 

 
When the vending machine detects that a battery is low an error code will be displayed (51). This code will remain on 
display until the battery has been replaced and the black reset button has been pressed. 
When the vending machine detects that a battery is dead, the machine will permanently turn itself off.

 

 

Section 2 
 

SERVICE MODE 

In this dedicated version of software the VMC is limited to 5 columns, each with a dedicated “negative counters” 
to count down the stock in each column. When the corresponding negative counter reaches zero the selection is 
shown as “

Sold Out

”. The capacities for each column are set with the “

nC

“ menu option. If all columns are sold 

out coin acceptance is inhibited. 
 
The negative counters can be reset using the “

A

” or “

B

” buttons: 

 

A

” Button – unconditionally resets ALL counters to maximum capacity. The operation is confirmed with a long 

bleep and 

ALL r-ld

 on the display. 

 

B

” Button – only resets any counters that are zero (i.e. fully vended)to their maximum capacity. Counters that are not fully 

vended are not changed. The operation is confirmed with a long bleep and 

r-ld

 on the display.

 

 

Operation

 

The operation of the machine can be adjusted by entering service mode by pressing the red button on the VMC 
circuit board and then accessing the appropriate operation. Price setting, coin value setting, and vend-credit criteria 
can be read and adjusted from here. The user can also perform tests on the machine through this mode. Note: any 
Credit will be cancelled on entry to Service Mode. 

Summary of Contents for SL5000

Page 1: ...Rev 2012 02 27 1 SL5000 Operator s Manual...

Page 2: ...n this process It is important that you keep the original packaging for your vending machine at least through the warranty period If your machine needs to be returned for repair you may have to purcha...

Page 3: ...M The delivery system of your SL5000 incorporates a Selection Pad an LCD Display and helix coils The customer inserts money into the coin slot and enters their selection on the Selection Pad the selec...

Page 4: ...0 seconds When the machine goes to sleep the following messages are displayed under set conditions When Awake When Asleep i 00 00 09 00 0 00 9 99 Decimal points always on ii 10 00 99 99 10 00 99 99 De...

Page 5: ...goes to Sleep 3 Service Mode can be exited by stepping through all the menu options using the Service Button or automatically if there is no activity for 30 seconds On Exit the software version numbe...

Page 6: ...ammed 4 Insert additional coins if required and repeat for other selections 5 Press Service Button to scroll to exit Prices may be set from 00 00 to 99 99 depending upon coin values The default price...

Page 7: ...nd Price Held until power removed Returned when ER pressed or held until power removed 05 Credit Vend Price Held for 60 seconds Returned when ER pressed or held for 60 seconds 06 None Free Vend Mode N...

Page 8: ...til Displays tE 2 Press Service Button to exit In Test Mode pressing a selection switch will operate the selected motor If a coin is inserted its value will be displayed for 1 second ALL MOTORS MODE 1...

Page 9: ...d Replace the battery 73 Battery nearly low Warning Replace recharge the battery soon Soft Errors unit will continue to operate though failed motors will show as Sold Out and be blocked from operation...

Page 10: ...t so an approximate setting of the timing value needs to be set The vend cycle is the time from motor start when at home to motor end return to Home in seconds This translates directly to the timing v...

Page 11: ...as been selected and the represents the current value of the Negative Counter that has been assigned to that shelf is displayed in scrolling mode from shelf 1 to 5 3 Sold out Feature After setting the...

Page 12: ...done to verify correct operation of the machine Further tests are done on Power Up Button Press Coin Insertion and entering exiting Service mode These tests will generate the relevant fault code as n...

Page 13: ...lection 2 for seconds till Displays set The machine will automatically exit from service mode and display Out Of Ord e r 3 Press Red Service Button to re enter Service Mode and re configure settings F...

Page 14: ...ce Exit Service Mode 62 Escrow Return Time out Check Escrow unit Activate Test Sequence Exit Service Mode 70 EEPROM Write Error Check Prices and Coin data 71 EEPROM Read Error Check Prices and Coin da...

Page 15: ...ution and reassemble COMMON QUESTIONS AND ANSWERS Q How High Can I set my Prices A Each selection can be priced individually up to 99 99 Q Can Customers reach down and help themselves to product A No...

Page 16: ...service repair alteration or disassembly has been performed Any defects caused by improper power source poor water quality or pressure an installed water filtration system not fully functioning abuse...

Reviews: