![Seaga OD14F User And Service Manual Download Page 19](http://html.mh-extra.com/html/seaga/od14f/od14f_user-and-service-manual_1221709019.webp)
Rev. 2013.08.19
19
IMPORTANT: THE MOTOR HOME AND COUNT FUNCTION SHOULD NEVER BE USED WHEN
PRODUCTS ARE LOADED AND THE DOORS ARE CLOSED. ALL SELECTIONS WILL VEND
IN SEQUENCE AND SERIOUS PRODUCT JAMS WILL OCCUR.
TEMPERATURE SETTINGS
1. Press the scroll buttons (
9
and
10
) repeatedly until
**
shows the current state
Displays tS.**
This menu option allows the zone temperature settings to be displayed and modified.
The first digit is the ON/OFF state: 0 means that the zone control is OFF
1 means that it is ON
The second digit shows the temperature scale currently in use:
F means Fahrenheit
C means Celsius
Examples:
tS.1F
Zone control is ON, temperatures in Fahrenheit
tS.1C
Zone control is ON, temperatures in Celsius
tS.0F
Zone control is OFF, temperatures in Fahrenheit
In this mode, press the selection buttons listed below to set mode and temperature limits
1 Turn the Zone
ON
.
2 Turn the Zone
OFF.
3 Set
the
LOWER
Limit control temperature - Press 2 digits in turn to set
the temperature (00 - 99). Any other alpha key will cancel the operation.
Lower limit - minimum 1°
C (34F) maximum 11° C (53° F).
4 Set
the
UPPER
Limit control temperature - Press 2 digits in turn to set
the temperature (00 – 99). Any other alpha key will cancel the operation.
Upper Limit - minimum 3° C (37° F) maximum 13° C (56° F)
.
Upper limit
to be set at least 2° C above the lower limit.
5 Select Celsius (Centigrade) temperature display.
6
Select Fahrenheit temperature display.
END MENUS DISPLAY
END
Menus
Displays
En.--
Exit Service Mode by selecting the END option and press any key other than 9 or 10, or the menus
function will end automatically if there is no activity for 30 seconds.