![Seaga OD14F User And Service Manual Download Page 17](http://html.mh-extra.com/html/seaga/od14f/od14f_user-and-service-manual_1221709017.webp)
Rev. 2013.08.19
17
The control word options supported are :
Code Multivend
Forced
Vend
1
No – single vend
No
2
Yes - multivend
No
3
No – single vend
Yes
4
Yes - multivend
Yes
SOUND (ON/OFF)
1. Press the scroll buttons (
9
and
10
) repeatedly until
Displays So.00
2. Press Selection Button
1
to toggle the setting
Displays So.01
3. Press any other Button to exit to the next menu option
A value of 1 enables the sound, 0 disables the sound.
***RECOMMENDED CODE:
1 (ON)
DISPLAY ERRORS
1. Press the scroll buttons (
9
and
10
) repeatedly until
Displays Er.-
-
In this mode, press any selection button (other than
9
or
10
) to display error codes in sequence,
shown as Er.nn where nn is the error number.
ERROR CODES
Error Code
Number
Fault detected
Hard/Soft
fault
Action
01 .. 60
Motor A1 .. F10 respectively
Soft
Repair/replace motor/home switch
70
Refrigeration Error
Hard
Check connection to temperature
sensor, check connection to Aux
Terminal on main control board
80
Coin Changer fault
Hard
Repair/replace coin changer or
disable the coin changer
81
Changegiver Out Of Change
Soft
Fill Tubes
82
Error in credit value
Soft
None
85
MDB Bill Reader fault
Hard
Repair/replace Bill Reader or disable
the bill reader
90
MDB Card Reader fault
Hard
Repair/replace Card Reader or
disable the Card reader
91
Error in Bill credit value
Soft
None
Soft Errors
– unit will continue to operate though failed motors will show as “Sold Out” and be
blocked from operation if selected.
Hard Errors
– the unit is put out of service. This mode can only be cleared via the menus.
CLEAR ERRORS
1. Press the scroll buttons (
9
and
10
) repeatedly until
Displays CE.-
-
In this mode, press any selection button (other than 9 or 10) to clear all errors – confirmed with a
“CLr” display.