DOCS-001 Manual, SeaBotix Inc. Users, 150 – 200 Series - Rev B – 27 Jan 10 -
Page 31 of 64
2.3.5
Diagnostics
Menu
1. SYSTEM
allows access to thruster status information; RPM temp, serial
number current, and fault code if any. RPM is not displayed for SBT150
thrusters.
2. Software Version
a. Pressing the 2 key will allow you to view the current software versions.
This information is important when technical assistance is required.
CC –Operator Control Unit
ROV – LBV Operational Program (Flash Program.)
BL – Boot Loader
TMC – Thruster Motor Controller
SB – Sensor Board
VPS – Vehicle Power Supply
3. Hours Run
a. Pressing the 3 key will allow you to view the number of hours that the
LBV has been powered up.
4. Display Ext. Temp
a. Pressing the 4 key will display the internal temperature of the LBV
where the external temperature is normally displayed. When you exit
the menu the temperature reading resets to the external temperature.
2.3.6
Options
Menu
1. Camera Rotate
a. Pressing the 1 key will allow you to turn camera rotate on and off.
Camera rotate allows the user to select how the camera rotate responds
when the CAMERA button is pushed on the operator control unit. Turn
camera rotate on when you wish to view the same perspective on each
camera as you switch between the two. Turn camera rotate off when you
wish to use the first camera to look straight ahead and the second to look
down.
2. Audio Channel
a. Pressing the 2 key will allow the user to switch between the internal
microphone or the optional external hydrophone.
3. Camera Tilt