20
INSTALLATION OF THE MINI TANK MECHANICAL LIMIT SWITCH STOPS
(Accessories on request)
- Release the unit (as in Fig. 56 to 61).
- Let the rod come out about 3/4 of its run.
- Put the limit switch stops on the front flange of the unit with the two rods (of the three which are
present on the stop) which are in parallel to the gate (Fig. 29).
- Fix the stop with the two included screws.
- Put the provided bush
(A)
into the rod.
- At this point hook the rod on the front fixation.
- To adjust the stop in opening act on disc, and in closing on disc 2.
Attention: the mounting of the mechanical stop does not cause the reduction of the stroke.
Fig. 29
Fig. 30
A
MINI TANK KIT MECHANICAL STOPS
(optional)
Rod in parallel to the gate
Disc 2
Disc 1
Very Important:
make sure that the two discs A and B perfeclty fit in opening phase
A
B