Maintenance
ST24 Ku-Band TVRO
6-2
6.2.
Touch Screen Calibration
If the icons on the GACP are non-responsive, it may require you to re-calibrate the touch screen itself. Use the
following procedure.
Install a straight 9 wire serial cable from the GACP’s
M&C port to an available com port on a
computer/laptop with Sea Tel Program Terminal
(ProgTerm) Installed.
If not already, apply power to the GACP.
Open up ProgTerm and select Coastal PCU to Panel
Translation mode.
In the main ProgTerm window, type in “&TC
<ENTER>”
That’s a dollar sign ($) capital T (T), capital C (C)
carriage return.
Follow the on-screen instructions to calibrate screen.
Press the circle located in the bottom left corner of
screen.
Press the circle located in the upper left corner of
screen.
Press the circle located in the top right corner of
screen.