3.7.3.1.
J13 NMEA 0183
NMEA 0183 I/O connections. Wiring is:
Pin 1
RX+
Pin 2
RX-
Pin 3
TX-
Pin 4
N/C
Pin 5
GND
Pin6
N/C
Pin 7
GND
Pin 8
TX+
Pin 9
+12 VDC
3.7.3.2.
J12 Aux 232
Auxiliary wired RS-232 connection. Wiring is:
Pin 1 - GND
Ground
Pin 2 - Aux IN1
Modem Lock Input 1 - See modem setup chapter.
Pin 3 - Aux IN2
Modem Lock Input 2 - See modem setup chapter.
Pin 4 - GND
Ground
Pin 5 - SW1
Blockage/Modem Mute Output 1 - See blockage & modem setup
chapters.
Pin 6 - SW2
Blockage/Modem Mute Output 2 - See blockage & modem setup
chapters.
Pin 7 - SW3A
Dry Contact set 1 - Dry alarm contacts used to provide
(programmable) alarm output to other equipment/systems. Switched
outputs have ability to use 4.7K pull up or Pull Down and can provide
Current sink of 0.5 amps max. Contacts are
Normally Open
for No
Alarm state and are
Closed/Shorted
when the programmed alarm
state exists.
Pin 8 - SW3B
Pin 9 - SW4A
Dry Contact set 2 - Same as dry alarm contact set 1.
Pin 10 - SW4B
3.7.3.3.
J14 Aux 232
Wiring is:
Pin 1
N/C
Pin 2
RX
Pin 3
TX
Pin 4
N/C
Pin 5
GND
Pin6
N/C
Pin 7
GND
Pin 8
N/C
Pin 9
+12 VDC
Summary of Contents for 5012-91
Page 8: ......
Page 20: ...5012 91 Installation Manual Site Survey 2 8 This Page Intentionally Left Blank...
Page 52: ...5012 91 Installation Manual Setup Ship s Gyro Compass 6 4 This Page Intentionally Left Blank...
Page 74: ...5012 91 Installation Manual Setup Targeting 12 4 This Page Intentionally Left Blank...
Page 84: ...5012 91 Installation Manual Quick Start Operation 14 6 This Page Intentionally Left Blank...
Page 112: ...5012 91 Installation Manual DRAWINGS 19 2 This Page Intentionally Left Blank...
Page 117: ......
Page 118: ......
Page 119: ......
Page 129: ......
Page 137: ......
Page 138: ......