5012-91 Ku-Band Technical Specifications
5012-91 Installation Manual
18-11
18.2.
Regulatory Compliance
Regulatory Compliance
Survival Shock and Vibration
IEC-60721, MIL-STD-901D
Operational Shock and Vibration
Operational: IEC-60945, Survival: IEC-60721
and MIL-STD 901D
MIL-STD-167-1
EMI/EMC Compliance Ku-Band
ETSI EN 301 843-1 V1.4.1 (2004-06)
ETSI EN 301 489-1 V1.4.1 (2002-08)
ETSI EN 300 339 (1998-03)
IEC EN 60945:1997
Satellite Earth Stations and System (SES)
ETSI EN 301 428-1 V1.3.1 (2006-02)
ETSI EN 302 340 V1.1.1 (2006-04)
Safety Compliance
IEC EN 60950-1:2001 (1st Edition)
Environmental Compliance
RoHS
Green Passport
FCC ESV Compliance C-Band
NA
FCC ESV Compliance Ku-Band
47 C.F.R. § 25.222
FCC ESV Compliance Ka-Band
NA
Options
Bluetooth
18.1.
Cables
18.1.1.
Antenna L-Band IF Coax Cables (Customer Furnished)
Due to the loss across the length of the RF coaxes at L-Band, Sea Tel recommends the following 50 ohm coax
cable types (and their equivalent conductor size) for our standard pedestal installations. Type N male
connectors installed on the cables MUST be 50 Ohm connectors for the center pin to properly mate with the
female adapters we provide on the Base multiplexer panel and on the adapter bracket mounted inside the
radome next to the breaker box.:
Run
Length
Coax
Type
Typical. Loss @
1750Mhz
Shield
isolation
Center
Conductor
Size
Installed
Bend
Radius
Tensile
Strength
<100 ft
LMR-240
10.704 db per
100 ft(30.48 m)
>90db
0.056 In.
(1.42 mm)
2.5 In. (63.5
mm)
80lb
(36.3 kg)
up to
150 ft
LMR-400
5.571 db per
100 ft(30.48 m)
>90db
0.108 In.
(2.74 mm)
4.0 in.
(101.6 mm)
160lb
(72.6 kg)
up to
200 ft
LMR-500
4.496 db per
100 ft(30.48 m)
>90db
0.142 In.
(3.61 mm)
5.0 In.
(127 mm)
260lb
(118 kg)
Up to
300 ft
LMR-600
3.615 db per
100 ft(30.48 m)
>90db
0.176 In.
(4.47 mm)
6.0 In.
(152.4 mm)
350lb
(158.9 kg)
Summary of Contents for 5012-91
Page 8: ......
Page 20: ...5012 91 Installation Manual Site Survey 2 8 This Page Intentionally Left Blank...
Page 52: ...5012 91 Installation Manual Setup Ship s Gyro Compass 6 4 This Page Intentionally Left Blank...
Page 74: ...5012 91 Installation Manual Setup Targeting 12 4 This Page Intentionally Left Blank...
Page 84: ...5012 91 Installation Manual Quick Start Operation 14 6 This Page Intentionally Left Blank...
Page 112: ...5012 91 Installation Manual DRAWINGS 19 2 This Page Intentionally Left Blank...
Page 117: ......
Page 118: ......
Page 119: ......
Page 129: ......
Page 137: ......
Page 138: ......