4. Light Problems
Green light on sensor does not go off
•
Recheck attachment to the product
Green light on LE strip of splitter box is “on”
•
Verify that the sensor or shunt are properly plugged in.
(If it is a shunt, verify that the wire is not broken).
No lights
•
Make sure batteries are installed and the AC/DC power supply is
plugged in.
No lights on sensors
•
Verify that the strip is plugged into the alarm unit.
No lights on a specific sensor
•
Plug another sensor into at the same location
- If it lights up– Replace the original sensor.
- If no lights appear on the sensor once again and other
sensors on the same strip are lit– Make sure the socket is clean
without any foreign objects and that the connection pins extend in
the same manner as in other sockets.
Yellow light is not flashing
•
Light should flash every 10-15 seconds, if it does not, replace the
(2) two 9 volt batteries.
Troubleshooting the “LE” Alarm System
Key Systems (SK-103LE) or Keypad Systems (SK-103KLE)
If the problem is different from any mentioned above,
or if you cannot resolve the problem,
please call our Customer Service Department at 1-(800) 322-2435