background image

Se-Kure Controls,

®

Inc.

3714 Runge St. • Franklin Pk., IL 60131 • 1-(800) 322-2435 • Fax: (847) 288-9999

Rev.4/10/97

©1997 Se-Kure Controls,

®

Inc.

SCI-9568

Installation Instructions for the

“LE PLUS” System Parts & Accessories 

“LE PLUS” System Sensors & Adhesives

– Available in Standard 6' Cable Lengths - (PC/LE - Coiled) & (P/LE - Straight Wire) –

SK-905

Rectangular
Adhesive 
Pad

1" x 2"

1

1

/

4

" x 1"

7

/

16

" x 

11

/

16

"

1" x 1"

SK-906

Bug Sensor
Adhesive 
Pad

SK-908

Tie Sensor
Adhesive 
Pad

SK-909

Ant Sensor
Adhesive 
Pad

7

/

16

" x 

11

/

16

"

SK-909NP

Neopreme
Ant Sensor
Adhesive Pad

SKD-6165

Dual- Ant & Tele. Modular

SKD-6163

Dual- Ant & Mini Phone Modular

SKD-6161

Dual- Ant Sensor & Ant Sensor

SKD-0443

Dual- Rectangular & Tie Sensor

SKD-0453

Dual- Rect. & Collar Lasso 

SKD-0461

Dual- Rect. & Ant Sensor 

SK-997

Pneumatic (Air Tool) Sensor 

SK-965

Telephone Modular Sensor 

SK-927

Parallel Port Sensor 

SK-925

Serial Port Sensor 

SK-904

Rectangular Push-N-Go Sensor 

SK-110

Extra Key for Alarm Module 

SK-107LE

“LE” Splitter Box w/6 Modular Ports 

SK-943T

Tie Wrap

SK-10106LE

“LE” Strip Alarm w/6 Ports

SK-10112LE

“LE” Strip Alarm w/12 Ports

SK-99-623

Strip Clips

SK-1912

Rectangular Removal Tool

SK-1712

Round Removal Tool

SKP-200T

Wire (Tele. Plug) Removal Tool

SK-103LE

“LE” Alarm Module

SK-109

Extra Telephone “Shunt Plug”

SK-195

AC/DC Power Supply

SK-947-10

10' (Str. Wire) “LE” Extension w/Coupler

SK-953

Collar Lasso Sensor 

SK-902

1" x 1" Bug Sensor 

SK-943

Tie (No-See) Sensor 

SK-961

Ant Sensor 

SK-940

Rect. (Micro Switch) Sensor 

SKD-0425

Dual- Rect. & Serial Port Sensor

SKD-0465

Dual- Rect. & Tele. Modular 

SK-998

Microphone Sensor

SKD-0404

Dual- Rectangular & Rectangular

Sensor Connections: 

– To Lenses  (SK-943 Series Lens Sensor)

12.

Insert the Tie-Wrap into the Lens Sensor as shown in Fig. 5, and wrap it 
around the lens.  Pull the Tie-Wrap tight, and cut off the excess with wire 
cutters or scissors.

Sensor Connections: 

– To Cameras with Removable Lenses  

(SKD-0443 Series Dual Sensor)

13.

The Dual Sensor, (shown in Fig. 6) is a combination of the Rectangular 
Sensor and the Lens Sensor for cameras with removable lenses.  Follow 
Steps 9 thru 12 for installation procedures.

Sensor Connections: 

– (SK-953 Series Collar Lasso Sensor)

14.

The Collar Lasso Sensor has a wire connector that loops around the 
product and plugs back into itself using a telephone modular plug.

15.

The Collar “Lasso” can be installed onto products be “Lassoing” any 
enclosed part of the product and plugging this module back into itself, 
(see Fig. 7).

Testing the System:
16.

With all sensors plugged into Splitter Boxes or Strip Alarms, and Shunt 
Plugs in all unused Ports, the GREEN light on the front of the Alarm Module
should be “out”.  Turn the Alarm Module key “Counter Clockwise” to the 
“ON” position.  The Alarm should remain silent.

15.

Remove (1) plug from a Sensor Port and the alarm should (((sound))) with 
that sensor port’s 

GREEN

indicator light “ON”.  This indicates an “open cir-

cuit”.  Turn the key “Clockwise” to the “OFF” position, Re-Install the plug in 
the sensor port, and turn the “Counter Clockwise” back to the “ON” position 
and remove.

THE ALARM IS NOW OPERATING!

NOTE: For Safety. . . Cables Should Be 18" Above the Floor.

Fig. 5

Fig. 6

Fig. 7

SK-943T

Tie-Wrap

SKD-0443 

Dual Sensor 

SK-953 

Collar Lasso Sensor 

SK-943 

Tie Sensor 

Summary of Contents for LE PLUS

Page 1: ...Adhesive Pads SK 195 AC DC Power Supply SK 961PC LE 6 Coiled Ant Sensor w Tie Wrap SK 953PC LE 6 Coiled Collar Lasso Sensor SK 904PC LE 6 Coiled Rectangular Sensor SKD 0453PC LE 6 Coiled Dual Sensor Collar Lasso Rect Stop Display Product Theft The LE PLUS Alarm System protects all Display Merchandise using the SK 103LE Kord Kontrol Alarm Module SK 103LE Splitter Boxes SK 10106LE SK 10112LE Strip A...

Page 2: ...ic Air Tool Sensor SK 965 Telephone Modular Sensor SK 927 Parallel Port Sensor SK 925 Serial Port Sensor SK 904 Rectangular Push N Go Sensor SK 110 Extra Key for Alarm Module SK 107LE LE Splitter Box w 6 Modular Ports SK 943T Tie Wrap SK 10106LE LE Strip Alarm w 6 Ports SK 10112LE LE Strip Alarm w 12 Ports SK 99 623 Strip Clips SK 1912 Rectangular Removal Tool SK 1712 Round Removal Tool SKP 200T W...

Page 3: ...and the sensor with Alcohol Prep Pads Wipe these surfaces DRY with a clean paper towel If the paper towel shows dirt REPEAT THIS CLEANING STEP until the surfaces are CLEAN DRY 10 Remove an SK 905 1 x 2 Rectangular Adhesive Pad from its backing sheet Apply the adhesive pad to the bottom of the sensor making sure that the center hole of the adhesive lines up with the plunger on the bottom of the sen...

Page 4: ...g 2 ...

Page 5: ...e x 11 16 dular sor ensor odule 0112LE 12 Ports nt Plug ensor ...

Page 6: ...d in them All sensor lights must be red if not recheck attachment to product No Alarm Make sure batteries are installed and the AC DC power supply is plugged in 2 Beeping Single beep ever 30 seconds Unit is disarmed arm either by turning key on or by keying in the proper code Double beep Indicates low batteries replace batteries 3 Keypad System Cannot activate or de activate the alarm system Make ...

Page 7: ...s plugged into the alarm unit No lights on a specific sensor Plug another sensor into at the same location If it lights up Replace the original sensor If no lights appear on the sensor once again and other sensors on the same strip are lit Make sure the socket is clean without any foreign objects and that the connection pins extend in the same manner as in other sockets Yellow light is not flashin...

Page 8: ...ion is not complete Step 2 Splitter Box Strip Lights GREEN Sensor Port Lights If this light is lit and No Sensor is plugged into the port Insert a Shunt Plug and re set the alarm If this light is lit and a Sensor is plugged in to that port the Sensor connected to the port is disconnected or ajar from the product If this light is dark The Sensor is connected properly Step 3 Sensor Lights WHITE If t...

Page 9: ...de on the keypad to place the system in a Stand By Mode The Keypad System features a device called Auto Arm It is intended to automatically arm the system after 4 minutes Operation of the Keypad Lock System When power is first applied to the device it will use the factory de fault code of 1 2 3 4 The user should change this code as soon as possible The system will accept the default code until a n...

Page 10: ...hown and push firmly onto printed circuit board Low Battery Power Alarm Light will flash and alarm will chirp when batteries need to be replaced Se Kure Controls Inc 3714 Runge St Franklin Pk IL 60131 1 800 322 2435 847 288 1111 Fax 847 288 9999 Rev 7 22 04 SCI 9760 2004 Se Kure Controls Inc ...

Page 11: ...he center hole has been removed from the adhesive apply it to the cleaned surface on the bottom of the rectan gular sensor Press it firmly into place see Fig 3 Remove the backing sheet from the other side of the adhesive pad and position the rectangular sensor over the flat area of the product previ ously cleaned Press the sensor firmly into place to insure a proper bond see Fig 4 The light on the...

Page 12: ...in the Stand By position and lift off the cover 2 Install 2 two new 9 volt Alkaline such as Duracell batteries not included inside the LE Alarm Box by first positioning them on the connectors attached to the circuit board and then pushing them firmly into place as shown in Fig 1 to the right The Power Test Light yellow should flash indicating that the power is on This light will flash every 15 sec...

Page 13: ...g from the Junction Splitter and plug a 48 SK 99 48J Extension into that port 8 Remove the Velcro backing from a SK 107J Junction Box and place it over the slot at the beginning of the slatwall 9 Plug the other end of the 48 Extension from the Junction Splitter into the side of the Junction Box and a 12 SK 99 12J Extension into the other side 10 Each row should be connected with Junction Box 12 Ex...

Page 14: ...p Ground GREEN connect eyelet to center screw on standard outlet plates Installation Instructions Special Note Make all connections before installing batteries and connecting the AC DC Power Supply Indoors 1 Screw the Alarm Module s Green Ground Wire to the ground screw located on the center of a grounded 110v AC outlet cover plate and plug the AC DC Power Supply into the outlet Hold off until the...

Page 15: ...o place the system in the Stand By Position before removing security screws Outdoors continued 4 Connect a SK 947KB Outdoor Product Cable to the SK 907KB Outdoor Splitter 5 Pass the cable s through an enclosed area of each product such as spokes or steer ing wheels to protect all the display merchandise in the line as shown above 6 Thread the end of an SK 947KB Outdoor Cable through the loop of a ...

Page 16: ...gh the wall to the exterior of the building 4 Caulk the hole around the cable 5 Flex the wall plate to get the cable through the slit to the center of the plate 6 Fasten the wall plates to the walls with the appropriate fasteners 7 To weather seal caulk the wall plate slit DO NOT CUT REWIRE THE CABLE Wall 6 to 12 Exterior Interior 1 Hole through Wall Wall Plate Slit Connector Ring Side Of Cable Fa...

Page 17: ...ge Street Franklin Park IL 60131 1 800 322 2435 847 288 1111 Fax 847 288 9999 web www se kure com e mail sekure msn com Rev 5 20 99 SCI 9637 1999 Se Kure Controls Inc CENTER 1 INCH HOLE HEIGHT Indoor Wall Plate Template Outdoor Wall Plate Template 1 5 8 1 5 8 CENTER 1 INCH HOLE HEIGHT 1 5 8 1 5 8 ...

Page 18: ...hem down until they snap onto their connectors Make sure the positive and negative line up properly Step 3 Replacing the Cover Place the cover back on the Alarm Module and replace the 4 screws you removed to get the cover off Step 4 Applying Ant Sensors As shown in Fig 3 at right remove the backing sheet from the adhesive and apply it to the sensor Remove the other backing sheet and apply the sens...

Page 19: ... a solid flat surface on the merachandise Arm the System With light RED and properly attached turn the key counterclockwise and remove the key to arm the system Put the key in a safe location Re Arming the System After An Alarm After an alarm has been set off insert the key in the Alarm Module and turn the key clockwise to the Stand By position Clean Dry the Ant Sensor and the area on the product ...