SK-195
AC/DC Power Supply
SK-403/961C
Alarm Module w/Coiled Ant Sensor
Final Assembly & Operating Instructions:
Plug the AC/DC Power Supply into any standard 110v AC outlet, and the mini connector
into the back of the Alarm Module. (Make sure the key is in the (clockwise) Stand-By
Position).
The sensor must be securely attached so the plunger on the sensor is
depressed.
• If the Alarm sounds during the stallation, check the sensor to make sure that the
plunger on the sensor is placed against a solid flat surface on the merachandise.
Arm the System
• With light RED and properly attached, turn the key (counterclockwise) and
remove the key to arm the system. (Put the key in a safe location).
Re-Arming the System After An Alarm
• After an alarm has been set off, insert the key in the Alarm Module and turn the key
(clockwise) to the Stand-By position.
• Clean & Dry the Ant Sensor and the area on the product where it is to be attached.
• Apply the sensor to the merchandise with a new SK-909 Ant Sensor Adhesive.
• If the sensor cable has been cut or damaged, call your Se-Kure Controls Customer
Service Representative for repair service.
Battery Testing
• Unplug the AC/DC Power Supply from the Alarm Module,
and press the “Battery Test Button.
• If the horn sounds, the batteries are ok.
• If the horn does not sound, or is weak, replace the
(2) 9V Alkaline Batteries.