Promask / Promask 2
19
With a blower device
The blower must be running
while using the respirator. If the blower turns off by accident, the
device ceases to function as a respirator, and carbon dioxide levels may instantly rise. This is
considered an exceptional situation.
At a very intense working pace, the pressure in the facepiece can change into negative pressure
at peak inhalation.
Protection levels may be reduced if wind speed exceeds 2 m/s.
Filters must not be fitted directly to the breathing hose.
Selection
Promask/Promask
2
+ filter
Breathing protector equipped with filter
Type of protective
device
Multiples of threshold concentration **)
Remarks, limitations
APF (Assigned protection factor)
BS 4275 (GB) BGR 190-ZH1/701 (DE)
Full face mask with
particle filter P3
40
400
Particles
Full face mask
with gas filter *)
20
400
Filter types A, B, E, K, AX, SX,
Hg-P3 and NO-P3 have different
applications. For more information,
see Instructions for Use of
Scott
Safety
filters.
Device with
combined filter
The specified multiples of threshold value for the gas or particle filters are
given separately, but in all cases the lowest value applies.
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not
exceeded. For non-powered filtering devices with gas filter, concentration must not exceed 0.1
vol.% in gas filter class 1 and 0.5 vol.% in gas filter class 2 and 1.0 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.
Note!
In Australia only, the following limitations apply:
Provides P3 protection only with a full face respirator (AS/ NZS 1716:2012 refers).
Provides P2 protection with a half face respirator negative pressure respirator
P blower device
Blower-assisted breathing protector equipped with filter
Type of protective
device
Multiples of threshold
concentration **)
Remarks, limitations
APF (Assigned protection factor)
BS 4275 (GB) BGR 190-ZH1/701
(DE)
Power-assisted full
face mask with particle
filterTM3P
40
500
Power-assisted full face
mask with gas filter *)
TM3 gas filter class 1, 2
or 3
40
500
For devices with combined filter
apply the relevant limitations of
gas and particle filters
Device with combined
filter
The specified multiples of threshold value for the gas or particle filters
are given separately, but in all cases the lowest value applies
*) Provided that the maximum permissible detrimental gas concentration for the gas filter is not
exceeded. For power-assisted filtering devices with gas filter, concentration must not exceed
0.05 vol.% in gas filter class 1 and 0.1 vol.% in gas filter class 2 and 0.5 vol.% in gas filter class 3.
**) If national guidelines exist: in all cases the lowest value applies.