Operational Characteristics 1600 lb system
Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F.
System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
Headmaster maintains a minimum discharge
pressure during freeze of:
·
217 PSIG + 25, -15 PSIG
CPR Valve Setting: 55 - 60 PSIG.
Note: CPR allows a maximum low side pressure at
the CP unit’s compressor. Maximum only occurs
during harvest.
Refrigerant Charge
·
288 oz
Compressor Amps
·
Single Phase - 15
·
Three Phase - 8
Batch Weight: 19 - 20 lb
Discharge Pressure Cut Out Switch
·
Cuts Out at: 450 PSIG
·
Resets at: 350 PSIG
Compressor: CS20K6E
Expansion Valves: 1
Eclipse
ä
1300,1600
September 2003
Page 45
70/70/50
90/90/70
120/110/100
Freeze
15 to 16 minutes
17 to 18 minutes
28 to 29 minutes
Harvest
2 ½ minutes
1 ½ minutes
1 ½ minutes
70/70/50
90/90/70
120/110/100
Suction at Ice Making Section, end of Freeze
35 to 37 PSIG
35 to 37 PSIG
40 to 44 PSIG
Suction at Ice Making Section, Harvest - Peak
70 to 80 PSIG
80 to 100 PSIG
120 to 140 PSIG
Discharge at Condensing Unit: Freeze - 5 minutes in
230 to 250 PSIG
250 to 270 PSIG
370 to 390 PSIG