Other Maintenance
The remote air cooled condenser coil must be
cleaned occasionally to keep the system operating
at high efficiency.
·
Remove any large debris from the outside of the
coil.
·
Vacuum accumulated dust.
·
Wash out the coils with water.
Caution: Do NOT use excessive water pressure as
that will bend the fins.
·
Straighten any damaged fins with a fin comb.
·
If the coils have become coated with grease, a
coil cleaner will have to be used to wash the
coils.
Disconnect power to the condensing unit and
remove the condenser top.
·
Inspect the fan blade to be sure it is not cracked
and is clean.
Return the condenser top to its original position
and reconnect the power supply.
Eclipse
ä
1300, 1600
September 2003
Page 36
Moving Parts Hazard
Rotating fan blade can
cause cuts
Disconnect electrical
power before removing
condenser top or fan
guard.