Ice Making Section
The CME1386 and CME1686 are similar in layout.
They differ in evaporator count, controller, float
stem and vapor inlet valve.
Major Components:
TXV -
one feeding a refrigerant distributor
Water Pump
- same for both models
Water Level Sensor
- signals reservoir water level
to the controller
Controller
- operates both the ice machine section
and the compressor unit.
Drain Valve
- opens to allow pump to drain the
reservoir
Water Inlet Valve
- 2.77 GPM solenoid valve that
opens to fill the reservoir
Low Side Access Valve
- allows connection for
diagnosis of ice machine section refrigeration
operation. Not for recovery.
Liquid, Vapor and Suction
Connections
- where the
pre-charged tubing kits
connect to.
Eclipse
ä
1300, 1600
September 2003
Page 14
Water
Pump
Water
Level
Sensor
Drain Valve
Water Inlet
Solenoid
Valve
Freezing
Compartment
Low Side
Access Valve
Vapor
Connection
Liquid
Connection
Suction
Connection
TXV
Controller
Front Ice
Sensor
Bin
Thermostat
Vapor Inlet
Valve