Tightening torques for screws
Tightening torques to mount the clamping system on the
machine table
(screw quality 10.9)
Screw size
M4 M5 M6 M8 M10 M12 M14 M16 M18 M20 M22 M24
Admissible torque
M
A
(Nm)
4.2 7.5 13
28
50
88
120 160 200 290 400 500
Tightening torques to mount top jaws on the TANDEM clamping
block
(screw quality 12.9)
Screw size
M4
M5
M6
M8
M10 M12 M14 M16 M20 M24
Tightening torques
M
A
(Nm)
5
9
15
32
62
108 170 262 510 880
Tightening torques to mount the chuck piston onto the cylinder
piston
(screw quality 12.9)
Screw size
M5
M8
M10
M12
Tightening torques
M
A
(Nm)
9
32
62
108
Assembly
The numbers shown for individual components refer to the
assembly illustrations or clamping block connections and to the
"Drawings" chapter.
Make sure the power supply for the clamping block is off during
assembly and connection. See chapter "Basic Safety Notes".
Assembly of the clamping block on the machine table
•
The clamping block must be partly built into the table top. The
cover (item 5) is built into the table top via a mounting- or
through-hole. To mount the clamping block with the flat
bottom surface of the housing (item 1) to the machine table,
the cover must be built into a cylindrical mounting- or through-
hole in the table top. The cylindrical mounting hole should be
d 0.2 to + 0.4 mm wider than the Ø U of the clamping
block (see "Technical Data"
"Connections of the clamping block"
). The
clamping block is not positioned over the cover.
•
If installed vertically, the opening of the coolant drain (item 13)
must always face downwards
6
7
7.1