Trouble shooting
22
03.00|KSF plus, KSF-LH plus, KSF-F plus |en
Trouble shooting
The chuck jaws of the clamping block do not move
Possible cause
Remedial measures
Air supply is interrupted or
pressure is insufficient.
Check air supply
Connections unintentionally interchanged Check the connections.
Air connections that are not required
are not sealed
Check connections and close
Active air connections sealed
Check and open connections
Screw breakage on the chuck piston or
piston rod breakage
(e.g. due to overload)
Disassemble clamping block and
replace damaged parts
send to Schunk for repair
Clamping block does not complete stroke
Possible cause
Remedial measures
Chips or dirt between covering strip and
base jaws
Unscrew the covering strip (item 7) and
remove chips and dirt
Clamping force weakens
Possible cause
Remedial measures
Clamping block not sealed tightly
Check connection or sealing screws; reseal or
replace
Seals damaged
Disassemble clamping block
and replace all the seals (see sealing kit lists
Inadequate lubrication
Grease the lubrication nipples with LINOMAX
200 (see chapter "Maintenance and Care"
Clamping block moves jerkily
Possible cause
Remedial measures
Steel guide rollers on sliding surfaces not
greased
See chapter "Maintenance and Care"
8