Maintenance and care
32
12.03|SRU 20 - 60|en
Disassembling the center position (variant M and VM)
WARNING
Risk of injury due to spring forces!
There is a pre-loaded compression spring in the interior.
• Carefully disassemble the module.
Position of the position numbers
1 Pull stops C and D out of the housing (14).
2 Remove the cover (18) of the adjusting sleeve (16).
3 Remove the stop piston (17).
4 Locked center position only:
Remove the locking ring (51) on the stop piston (17).
8.3.2