Maintenance and care
30
12.03|SRU 20 - 60|en
Maintenance and care
Maintenance intervals
NOTICE
At ambient temperature above 60°C the lubricants can
harden faster.
• Interval decrease accordingly.
To ensure the function, we recommend regular testing of the seals
and the mechanism after around 4 million swivel movements, re-
spectively 2 million cycles.
Lubricants/Lubrication points (basic lubrication)
We recommend the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubrication point
Lubricant
the teeth and the pinion
LINOMAX
Metallic sliding surfaces
Renolit HLT 2
All seals
Renolit HLT 2
8
8.1
8.2