Assembly and Commissioning
12.03|SRU 20 - 60|en
21
Magnetic switch MMS 22
The magnetic switches can be mounted via four grooves in the
module housing. The setting of the switching positions
must be done as follows:
1 Turn the unit to the required swivel angle.
2 Push the magnetic switch into the groove.
3 Move the magnetic switch along the groove until it actuates.
4 Secure the magnetic switch. (see enclosed data sheet)
5 Check the switch position of the magnetic switch by swiveling
the module repeatedly.
NOTE
We recommend the use of four magnetic switches to monitor the
locked center position:
• One sensor each to monitor the two limit positions
• For monitoring approach to the center position from
end position 0°
• For monitoring approach to the center position from
end position 180°
6.7.1