Maintenance and care
36
01.01|RP / RW / RC 1212-2128|en
Maintenance and lubrication, rotary module RM...
Shock absorber
NOTICE
Serious mechanical damage due to failure of the shock absor-
bers.
The shock absorbers have a limited service life span. A shock ab-
sorber failure can lead to serious mechanical damage; for this
reason, they must be checked regularly for proper function. The
shock absorber is working correctly if the device reaches its end
position swiftly without any mechanical impact.
Overloading of the unit or exceeding the permitted swivel speed
can lead to drastic reduction of the service life.
•
Determine the swiveling times and the permitted stroke fre-
quency with "Gemotec Toolbox".
•
Regularly check the shock absorber.
•
Observe the recommended maintenance intervals.
Maintenance and lubrication intervals
NOTICE
At ambient temperature above 60°C the lubricants can
harden faster.
•
Interval decrease accordingly.
Maintenance measures
Interval [Mio. cycles]
Check for leaks
2
Replace shock absorber
2 (recommendation for safe
operation)
Re-lubricate the gear rack and pinion unit
(RM15, RM21)
4 (recommendation)
11.2
11.2.1
11.2.2
www.comoso.com