Assembly
08.00 | PZN-plus | Assembly and Operating Manual | en | 0389374
35
Variant Dust-tight:
Before attaching the sensor, remove the sealing bolts from the
bracket. Before adjusting the control cam, unscrew the set-screw
from the side cover.
Ø
Move product to the "gripper open" position.
Ø
Loosen screw (4) and remove control cam (6) for the inductive
monitoring from the base jaw.
Ø
Remove screw (5) from the base jaw.
Ø
Slide control cam (7) out of the mounting kit with the recess at
the front into the base jaw.
Ø
Screw the control cam (7) to the base jaw using the screw (8).
Ø
Slide spacer shim (9) into the bracket (2) to the stop.
Ø
Slide the sensor (1) to the stop into the bracket (2).
Ø
Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
Ø
Adjust sensor (1), see Translation of Sensor Assembly and Oper-
ating Manual.
Variant Dust-tight:
Screw in set-screw into the side cover.
5.3.12 Mounting the analog position sensor APS-M1
To be able to mount the sensor, the gripper has to be retrofitted
with a special mounting kit.