Maintenance and care
08.00|PGB 64 - 125|en
31
Maintenance and care
Notes
Original spare parts
When replacing damaged parts (wearing parts/spare parts) only
use SCHUNK original spares.
Replacement of housing and base jaws
The base jaws and the guides in the housing are matched to each
other. To have these parts replaced, send the complete module
along with a repair order to SCHUNK.
Maintenance and lubrication intervals
NOTICE
At ambient temperature above 60°C the lubricants can
harden faster.
• Interval decrease accordingly.
Maintenance- and lubrication interval
Interval [Mio. cycles]
2
Lubricants/Lubrication points (basic lubrication)
We recommend the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point
Lubricant
Metallic sliding surfaces
microGLEIT GP 360
All seals
Renolit HLT 2
Bores on the piston
Renolit HLT 2
In addition to the described maintenance, the guides of the grip-
per can be re-lubricated as needed by means of lubricating nip-
ples. The lubricating nipples can be used instead of the air purge
connection.
Remove the two set screws for the air purge connection and re-
place them with two conical grease nipples.
9
9.1
9.2
9.3
www.comoso.com