Assembly
24
08.00|PGB 64 - 125|en
NOTICE
Sensor can be damaged during assembly.
• Do not exceed the maximum tightening torque of 10 Ncm for
the set screws.
NOTE
Ferromagnetic material changes the switching positions of the
sensor. For example: Adapter plate made of ordinary steel.
At ferromagnetic adapter plates:
• The module must firstly be mounted on the adapter plate
• Then, the positions of the magnetic switch have to be set
1
2
Fig. 9
1 Slide or turn in the magnetic switch (1) into the groove until it
bears against the stop (2) (if available).
2 If there is no terminal stop, then slide the magnetic switch accord-
ing to dimension l2 (bottom edge of gripper up to front side of sen-
sor) or according to dimension l1 (bottom edge of gripper up to
double arrow on sensor) and then clamp with the mounting screw.
Dimension
Size
64
80
100
125
l
1
8,8
18,7
21,0
22,9
l
2
17,7
27,6
29,9
31,8
Mounting of the sensor
www.comoso.com