9.4
Release the two cylinder screws. (2)
Remove the adapter and swivel plate.
Clean and oil the contact surfaces, e.g. with MOTOREX Supergliss 68 K to ISO VG 68.
Place the adapter plate (1) on the fixed jaw.
Tighten the two cylinder screws (2) with 40 Nm.
Engage the swivel plate (4) and the swivel peg (5) in the clamping lever and check whether marking
(R) on swivel peg and swivel plate points outside.
Fit the cover plate.
Fitting the 6-fold reversible jaws
9.5
Determine the mounting positions of the 6-fold reversible jaws.
The best clamping results are achieved when clamping parts as far out as possible.
Move the cover screws so that the selected clamping position is available.
Position the 6-fold reversible jaws and loosely insert the cylinder screws.
Turn the 6-fold reversible jaws on to the required clamping faces and slightly pre-clamp the
workpiece with the clamping jaws so that the clamping faces are parallel to, and touch,
the workpiece.
Use a torque of 80 Nm to tighten the cylinder screws of the 6-fold reversible jaws.
Important:
When the clamping faces of the 6-fold reversible jaws are not aligned parallel to the
workpiece surface it is possible that the 6-fold reversible jaw becomes loose through the
clamping force
.