Start-up
6.5 Low-pass filter
The switch-on option is "no filtering" as standard. The filter setting
can be configured to reduce signal noise.
The limit frequency depends on the selected sampling rate, which
is listed in the following table. The limit frequencies for the
different sampling rates are listed in the following table and
diagrams:
Selected
filter
-3-dB cutoff frequency (in Hz)
at 0.5 kHz
sampling
rate
at 1 kHz
sampling
rate
at 2 kHz
sampling
rate
at 4 kHz
sampling
rate
at 8 kHz
sampling
rate
0
200
350
500
1000
2000
1
58
115
235
460
935
2
22
45
90
180
364
3
10
21
43
84
170
4
5
10
20
40
81
5
2.5
5
10
20
40
6
1.3
3
5
10
20
7
0.6
1.2
2.4
4.7
9
8
0.3
0.7
1.4
2.7
5
Damping
Frequency
Filter damping at 0.5 kHz sampling rate
29