background image

 

6

 

MAINTAIN MODE  

(FLOAT MODE MONITORING)

When the CHARGED/MAINTAINING 

 (green) LED is solid, the charger has 

started maintain mode. In this mode, the 

charger keeps the battery fully charged by 

delivering a small current when necessary. 

If the charger has to provide its maximum 

maintain current for a continuous 12 hour 

period, it will go into Abort Mode (see 

Aborted Charge

 section). This is usually 

caused by a drain on the battery or the 

battery could be bad. Make sure there 

are no loads on the battery. If there are, 

remove them. If there are none, have the 

battery checked or replaced. 

MAINTAINING A BATTERY

The DSR117 maintains 12 volt batteries, 

keeping them at full charge. It can charge 

and maintain both small and large 

batteries.

NOTE:

 The maintain mode technology 

allows you to safely charge and maintain 

a healthy battery for extended periods of 

time. However, problems with the battery, 

electrical problems in the vehicle, improper 

connections or other unanticipated 

conditions could cause excessive current 

draws. As such, occasionally monitoring 

your battery and the charging process is 

recommended.

12. MAINTENANCE AND CARE

A minimal amount of care can keep your 

battery charger working properly for years.

• Clean the clamps each time you are 

finished charging. Wipe off any battery 

fluid that may have come in contact with 

the clamps, to prevent corrosion.

• Occasionally cleaning the case of the 

charger with a soft cloth will keep the 

finish shiny and help prevent corrosion.

• Coil the input and output cords neatly 

when storing the charger. This will help 

prevent accidental damage to the cords 

and charger.

• Store the charger unplugged from the AC 

power outlet in an upright position.  

• Store inside, in a cool, dry place. Do not 

store the clamps clipped together, on or 

around metal, or clipped to the cables.

13. TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

The POWER   LED 

does not light when 

charger is properly 

connected.

AC outlet is dead.

Poor electrical connection.

Check for open fuse or circuit 

breaker supplying AC outlet.

Check power cord and extension 

cord for a loose fitting plug.

The battery is 

correctly connected, 

but the CHARGING 

 LED did not light 

immediately.

If the START/STOP button is 

not pressed, charging should 

begin in ten minutes.

No problem; this is normal.

The battery is 

properly connected, 

but the CHARGING 

 LED never lit.

The battery voltage is low.

Press the START/STOP button to 

start charging. 

Summary of Contents for DSR PROSERIES DSR117

Page 1: ...ollow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA USO En este manual le explica c mo utilizar el cargador de bater a de manera segura...

Page 2: ...PLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow the...

Page 3: ...position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in Sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS I...

Page 4: ...per connection can result in a risk of an electric shock or electrocution NOTE Pursuant to Canadian Regulations use of an adapter plug is not allowed in Canada Use of an adapter plug in the United Sta...

Page 5: ...t use for industrial applications POWER UP IDLE TIME LIMIT If the Start Stop button is not pressed within 10 minutes after the battery charger is first powered up charging will automatically begin whe...

Page 6: ...INTENANCE AND CARE A minimal amount of care can keep your battery charger working properly for years Clean the clamps each time you are finished charging Wipe off any battery fluid that may have come...

Page 7: ...o cool The battery may be too large or have a short circuit Have battery checked or replaced The battery capacity is too low or the battery is too old Have it checked or replaced The battery won t hol...

Page 8: ...g repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied...

Page 9: ...o o limpieza El simple apagado de los controles no reducir este riesgo 1 11 ADVERTENCIA RIESGO DE GASES EXPLOSIVOS a RESULTA PELIGROSO TRABAJAR EN FORMA CERCANAA UNA BATER A DE PLOMO LAS BATER AS GENE...

Page 10: ...salida se encuentre establecido en la tensi n correcta en su caso Si el cargador posee un ndice de carga ajustable cargue la bater a en el menor ndice en primer lugar 4 UBICACI N DEL CARGADOR 4 1 Ubi...

Page 11: ...a a la mayor distancia posible de la bater a Luego conecte el gancho NEGATIVO NEGRO del cargador al extremo libre del cable 7 5 No se ubique en posici n frontal a la bater a al realizar la conexi n fi...

Page 12: ...de CA o puede resultar en da os al cargador CARGA DE LA BATER A EN EL VEH CULO 1 Apague todos los accesorios del veh culo 2 Mantenga el cofre abierto 3 Limpie las terminales de la bater a 4 Coloque el...

Page 13: ...ja se encender FINALIZACI N DE LA CARGA La finalizaci n de la carga se indica con el LED CHARGED MAINTAINING verde Cuando est s lido el cargador ha pasado de modo de funci n a mantenimiento MODO DE MA...

Page 14: ...e ilumina El voltaje de la bater a todav a est debajo de 10V despu s de 2 horas de carga o En el modo de mantenimiento la corriente de salida es de m s de 1 5 A durante 12 horas La bater a est sulfata...

Page 15: ...sta garant a por lo accesorios utilizados con este producto que no sean los fabricados por Schumacher Electric Corporation y que no est n aprobados para su uso con este producto La presente Garant a L...

Page 16: ...IFS a IL EST DANGEREUX DE TRAVAILLER A PROXIMIT D UNE BATTERIE AU PLOMB LES BATTERIES PRODUISENT DES GAZ EXPLOSIFS EN SERVICE NORMAL IL EST AUSSI IMPORTANT DE TOUJOURS RELIRE LES INSTRUCTIONS AVANT D...

Page 17: ...EUR 4 1 Placez le chargeur aussi loin que possible de la batterie que les c bles CC le permettent 4 2 Ne jamais placer le chargeur directement sous la batterie charger les gaz ou les fluides qui s cha...

Page 18: ...raccordement 7 6 Pour interrompre l alimentation du chargeur mettre les interrupteurs hors circuit retirer le cordon C A de la prise enlever la pince raccord e au ch ssis et en dernier lieu celle racc...

Page 19: ...le capot ouvert 3 Nettoyez les bornes de la batterie 4 Placez le chargeur sur une surface s che et non inflammable 5 Posez les c bles CA CC l cart de toute pales de ventilateur courroies poulies et au...

Page 20: ...llume FIN DE CHARGE Ach vement de charge est indiqu par l op ration de CHARGED MAINTAINING vert LED Quand il est allum le chargeur est pass en mode de maintien de l op ration MODE DE MAINTIEN SURVEILL...

Page 21: ...at La charge ne progresse pas et la tension de la batterie est inf rieure 14 2 V La tension initiale de la batterie est inf rieure 12 2 V et le courant d entr e total est inf rieur 1 5 Ah La tension d...

Page 22: ...concernant les accessoires utilis s avec ce produit qui ne sont pas fabriqu s par Schumacher Electric Corporation et approuv s pour une utilisation avec ce produit Cette garantie limit e est annul si...

Page 23: ...ore Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For faster warranty activation go to www batterychargers com to r...

Page 24: ...r Electric Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 U Nom________________________________________________________________ Adresse_____________________________________________...